Survey on the Status of Protective Measures in Dental Radiography

Show simple item record

dc.contributor.author Abu khiar, AlTahir Abd Almalik
dc.contributor.author Supervisor- Nadia Omer Alatta
dc.date.accessioned 2014-03-10T10:06:13Z
dc.date.available 2014-03-10T10:06:13Z
dc.date.issued 2008-09-01
dc.identifier.citation Abu khiar, AlTahir Abd Almalik. Survey on the Status of Protective Measures in Dental Radiography/ AlTahir Abd Almalik Abu khiar; Nadia Omer Alatta.- Khartoum : sudan university of science and technology,Medical Radiologic Scince,2008.- 74p. : ill . ;28cm .-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/3841
dc.description Thesis en_US
dc.description.abstract This study deals with dental radiography and it covers the main dental department in Khartoum state. The survey study covered the main variables concerning physical characteristics of the x-ray equipment which focuses on mechanical and electrical stability, dark room integrity including processing chemistry, film speed, film processing and viewing conditions. X-ray beam parameters in terms of tube voltage, exposure time accuracy are tested in order to measure the x-ray tube performance in term of radiation output A designated questionnaire is distributed to dental practitioners who are physically running x-ray clinic and to x-ray technologists. It includes the selection criteria, the type of processing, reject analysis etc... The survey revealed that, there is no adherence to quality assurance cycle i.e. critical examination, acceptance testing procedures for the newly installed x-ray equipment, and routine performance testing. In addition there is neither quality assurance program, nor local rules. There is also a lack of agreed radiographic selection criteria to guide Sudanese dentists and this may lead to overuse of certain technique, principally panoramic radiography. The research reveals as well the enormous variations in patient dose for the same procedure. Dose for a given examination vary between clinics by a factor of 5. Much of this variation resulted from inadequate equipment or techniques. Such serious problem can be identified and resolved through an ambitious program of education, quality assurance and strict monitoring framework. Many factors can influence the dose required to produce a good quality image. These factors include: In intra-oral radiography, the use of fast (E-speed) film and rectangular collimation (instead of rounded collimator) offer dose reduction of approximately 50% and 60%, respectively. Constant potential X-ray unit and rare-earth filtration permit further reductions. In panoramic and cephalometric, improved collimation offers a simple means of dose limitation, while doses can be reduced by up to one-eighth by combining the use of constant potential X-ray units, rare-earth intensifying screens and rare-earth filtration en_US
dc.description.sponsorship sudan university of science and technology en_US
dc.language.iso en en_US
dc.publisher sudan university of science and technology en_US
dc.subject Status en_US
dc.subject Radiography en_US
dc.title Survey on the Status of Protective Measures in Dental Radiography en_US
dc.type Thesis en_US