Estimation of Thyroid Gland Dose and Radiation Risks to Patient undergoing Computed Tomography Examinations

Show simple item record

dc.contributor.author Ahmad, Rufida Elbushra Eisa
dc.contributor.author Supervisor-Abdelmoneim Adam Mohamed Sulieman
dc.date.accessioned 2014-03-02T09:44:46Z
dc.date.available 2014-03-02T09:44:46Z
dc.date.issued 2012-06-01
dc.identifier.citation Ahmad,Rufida Elbushra Eisa .Estimation of Thyroid Gland Dose and Radiation Risks to Patient undergoing Computed Tomography Examinations/Rufida Elbushra Eisa Ahmad;Abdelmoneim Adam Mohamed Sulieman.- Khartoum : sudan university of science and technology, Medical Radiologic science,2012.- 298p . P ill ;28cm .- M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/3721
dc.description Thesis en_US
dc.description.abstract Exposure to radiation over long time promotes the development of thyroid carcinoma. many of the papillary induced carcinomas of the thyroid are radiation-induced. This study was intended to estimate thyroid dose and the associated risk for thyroid cancer induced from common brain, chest and cervical spine examinations, Estimate thyroid organ dose and radiation risk of the thyroid. In this study a CT machine, NRPB software, ImPact software, ICRP, Most common types of diagnostic CT studies performed on consecutive adult patients at hospitals of Khartoum State. The data of this study were collected from Alnilain Diagnostic Center (Philips, Dual slice), Ibn Alhitham specialist (Toshiba, 4 slices) and Omdurman Military hospitals (Seimens somaton blues, 16 slice).it preformed for three organs chest, brain and cervical spine. The DLP, effective dose and thyroid dose was as fallow in Omdurman Military the chest values are (DLP=172,Effective.dose=2.40(mSv),Td.dose=1.68(mSv)), brain(DLP=610,Effective.dose=1.28(mSv),Td.dose=0.14(mSv)),c/s(DLP=38.56,Effective .dose=0.19(mSv),Td.dose=0.09(mSv))in Ibn Alhitham the chest value is (DLP=655.10 ,Effective.dose=9.17(mSv),Td.dose=6.41(mSv)),brain(DLP=756.70,Effective.dose=1.58(mSv ),Td.dose=0.17(mSv)),c/s(DLP=474.50,Effective.dose=1.47(mSv),Td.dose=6.41(mSv)) in Alnilain the chest value is (DLP=123.60, Effective.dose=1.73(mSv), Td.dose=1.21(mSv)), brain(DLP=144.50,Effective.dose=2.89(mSv),Td.dose=0.31(mSv)). In this study the radiation dose is higher in Ibn Alhutham hospital than the other two hospitals while the radiation dose in Al-nilain the lowest. The dose contribution from the chest exam to the thyroid is higher than the brain and cervical opine examination. en_US
dc.description.sponsorship sudan university of sciences and technology en_US
dc.language.iso en en_US
dc.publisher sudan university of science and technology en_US
dc.subject Tomography en_US
dc.subject Radiation en_US
dc.title Estimation of Thyroid Gland Dose and Radiation Risks to Patient undergoing Computed Tomography Examinations en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search SUST


Browse

My Account