USE OF X-RAYS IN NDT TEST IN SUDAN PIPELINES AND HOSPITALS : A COMPARTIVE STUDY

Show simple item record

dc.contributor.author Mohamed, Mousa Abd El Shafi Esmael
dc.date.accessioned 2014-02-12T12:29:25Z
dc.date.available 2014-02-12T12:29:25Z
dc.date.issued 2006-09-01
dc.identifier.citation Mohamed,Mousa Abd El Shafi Esmael .USE OF X-RAYS IN NDT TEST IN SUDAN PIPELINES AND HOSPITALS : A COMPARTIVE STUDY/Mousa Abd El Shafi Esmael Mohamed; Abd El Rahman Elhassan Mohamed-Osman.-Khartoum:Sudan University of Science and Technology,College of Science,2006.-57p. : ill. ; 28cm.-M.Sc. en_US
dc.identifier.uri http://hdl.handle.net/123456789/3471
dc.description Thesis en_US
dc.description.abstract In this thesis, the basic methods of Non-Destructive Testing (NDT) were discussed. In this study, the X-ray machines used in the oil pipeline were compared to that used in medical filed. From the comparison, it was found that, the machine used for oil pipeline needs high voltage (due to pipeline thickness) and long exposure time, while the one used for medical purpose needs low voltage (due to the nature of tissues) and short exposure time. While the radiographic films differ, and were found to, depend on the voltage used in the technique. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Physics en_US
dc.subject X-RAYS en_US
dc.title USE OF X-RAYS IN NDT TEST IN SUDAN PIPELINES AND HOSPITALS : A COMPARTIVE STUDY en_US
dc.title.alternative استخدام الأشعة في الاختبارات اللااتلافية دراسة مقارنة بين جهاز الأشعة السينية المستخدم في المجال الطبي ومجال فحص أنابيب البترول en_US
dc.type Thesis en_US