SUST Repository

Role of computed Radiolgraphy in imporving Radiological services

Show simple item record

dc.contributor.author Abdelmagid, Mohammed Elfatih Khalafalla
dc.contributor.author Supervisor - Motasim Ahmed Alsaid
dc.date.accessioned 2013-12-19T10:46:39Z
dc.date.available 2013-12-19T10:46:39Z
dc.date.issued 2009-04-01
dc.identifier.citation Abdelmagid, Mohammed Elfatih Khalafalla .Role of computed Radiolgraphy in imporving Radiological services/ Mohammed Elfatih Khalafalla bdelmagid; Motasim Ahmed Alsaid.- Khartoum : sudan university of science and technology,Medical Radiologic Science. 2009.-60p. : ill ;28cm .- M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/2854
dc.description Thesis en_US
dc.description.abstract The Computed Radiography now adays are more frequently used in the modern X-ray departments, because it used Photostimuble storage phosphor instead of film/intensifying screen which needs processing. This leads to measure change in the concept of technology application and the quality control system. This study has been conducted on Kalba, Old and new Hospital X-ray departments, its comparative study between CR and conventional radiography. The study carried out on the period of ten months. The main objectives of this study was to evaluate the impact of CR in the field of radiology. The results of this study was accounted by using reject films analysis which has been evaluated by an expert radiologists and technologists. The results show that there is high rate of conventional radiology 3.3% compare parameters has been to CR 0.56%. rejected films in Also the X-ray evaluated in term of quantity and quality for the patient; application of CR gives reduction of dose range from 25% to 50% while preserving the slandered quality of the image. Using of CR facilitate the use of :PACS and hence teleradiology in the hospital. The application of CR increases the productivity while reducing the running cost of X-ray department. Also the application of CR will reduce repetition rate the radiation dose to the respect to conventional which services. iv patients as well as the will speed the process of en_US
dc.description.sponsorship sudan university of science and technology en_US
dc.language.iso en en_US
dc.publisher sudan university of science and technology en_US
dc.subject Radiography en_US
dc.subject Radiologic en_US
dc.title Role of computed Radiolgraphy in imporving Radiological services en_US
dc.type Thesis en_US