SUST Repository

Assessment of Co-57 image uniformity tests for gamma camera system

Show simple item record

dc.contributor.author Ahmed, Omima Adam Sabil
dc.contributor.author Supervisor - Mohamed Ahmed Ali Omer
dc.date.accessioned 2013-12-17T09:54:43Z
dc.date.available 2013-12-17T09:54:43Z
dc.date.issued 2010-01-01
dc.identifier.citation Ahmed,Omima Adam Sabil .Assessment of Co-57 image uniformity tests for gamma camera system/Omima Adam Sabil Ahmed;Mohamed Ahmed Ali Omer-Khartoum : sudan university of science and technology,Medical Radiologic Science,2010-30p. : ill .;28cm .- M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/2822
dc.description Thesis en_US
dc.description.abstract Extracorporeal shock wave lithotripsy is considering the extensive world external treatment process for renal, uretric , bladder and gallbladder stones. This procedure is usually followed up by using x-ray fluoroscopy devices as localizer, the reason is that to optimize the absorbed dose of patients according to the recommendations of international organizations; the aim of this study is to measure the entrance surface dose and the probability of carcinogenesis regarding to x-ray fluoroscopy irradiating during ESWL. The study was applied in Al-Naileen diagnostic center (Group 1, 50 patient) and in Al-Khartoum advance diagnostic center (Group 2, 25 patients), the classification of patients was depending on the type of the lithotripter. The entrance surface dose measurements were done by using thermoluminescence dosimeter (TLDs) GR200A LiF. The mean entrance surface dose and mean effective dose were (0.38 mGy) and (0.34 mGy) for group1 and 2 respectively, the measured organ dose were (0.16 mGy), (0.02) and (0.01) for kidneys, intestines and ovaries. As it was observed Group1 was irradiated to higher dose than Group 2 that’s because of the x-ray fluoroscopy equipment in Group 1 has no ability to change the orientation of the machine without exposing the patient to radiation, thus the duration of irradiating is extended and as a result then increasing the entrance surface dose. The results show that the probability of carcinogenesis due to irradiating to the measured amounts of radiation exposures is a tiny value (1 for million patient) but the main biological effect is occur due to the cumulative impact of radiation. In addition the study insures that there is a correlation between the weights, irradiating factors and absorbed doses. As a result guiding charts, training courses for technologist and a strong quality assurance program were recommended to optimize the ESD for patients. en_US
dc.description.sponsorship sudan university of science and technology en_US
dc.language.iso en en_US
dc.publisher sudan university of science and technology en_US
dc.subject Measurement en_US
dc.subject radiation en_US
dc.title Assessment of Co-57 image uniformity tests for gamma camera system en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search SUST


Browse

My Account