Abstract:
In this thesis, the effect of changes of high voltage and emission current in XRay
Tube was verified on the rate of penetration through NaCl crystallization
(NaCL). Where was checked the effect of applied high voltage used to accelerate
electrons to produce X-ray also emission current were investigated as a function
of penetrating rate with different angle of incidence on sodium chloride (NaCL)
Crystal as nondestructive testing method the method was used in case of
changing the applied voltage and fixing the emission current to 1 mA it was
revealed increase of penetrating rate with increasing the applied voltage and
decreasing with increasing of angle of incidence.
In case of fixing the accelerated voltage at 35 KV and changing the emission
current (0.6, 0.8 and 1 mA) it was revealed logarithmic decay with higher
penetrating rate 1 mA than 0.8 mA.