SUST Repository

Evaluation of Magnetic Resonance Imaging Artifact in Medical Imaging Centers in Khartoum State

Show simple item record

dc.contributor.author El-bashir, Maram Kamal Mohamed
dc.contributor.author Supervisor, -Hussein Ahmed Hassan
dc.date.accessioned 2019-11-26T11:20:27Z
dc.date.available 2019-11-26T11:20:27Z
dc.date.issued 2019-07-18
dc.identifier.citation El-bashir, Maram Kamal Mohamed . Evaluation of Magnetic Resonance Imaging Artifact in Medical Imaging Centers in Khartoum State \ Maram Kamal Mohamed El-bashir ; Hussein Ahmed Hassan .- Khartoum : Sudan University of Science and Technology , College of Medical Radiologic Science , 2019.-71p. :ill;28cm.- M.Sc en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/23898
dc.description Thesis en_US
dc.description.abstract The aim of this study was to detect the MRI artifacts in medical imaging center in Khartoum and detecting their Causes and remedy made by the technologist to provide information that well serve as useful data base for MRI artifact . Using data sheet filling out by technologist observation to collecting the data along 3 month on Dar Alelaj Specialized Hospital . The result showed the motion artifact was the most dominant type of artifact which is 54% ,then software slice overlap and tissue heterogeneous were had the same percentage (16%) for each ,the MR hardware 8% and the lowest recurrent artifact observed was Fourier transform nyquist sampling by (6%). Through my observation for most common Artifacts in the magnetic resonance imaging centers in Khartoum state we found most common artifacts that is of patient movement (motion Artifacts) due to differentials reasons e.g.: unconscious patient ,lack cooperation and instruction , MR software slice overlap appear from not accurate planning , MR hardware & room shielding caused by some element of coil not working , and Fourier transform & nyquist sampling. The study conclude that the patient motion artifact is the most common .the study recommended that the patient should be instructed before exam and preventive maintenance for MR coils must be keep on . en_US
dc.description.sponsorship Sudan University of Science & Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic Sciences en_US
dc.subject Medical Diagnostic Imaging en_US
dc.subject Magnetic Resonance Imaging Artifact en_US
dc.subject Medical Imaging Centers en_US
dc.title Evaluation of Magnetic Resonance Imaging Artifact in Medical Imaging Centers in Khartoum State en_US
dc.title.alternative تقويم تشوهات صور الرنين المغنطيسي في مراكز التصوير الطبي في ولاية الخرطوم en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account