SUST Repository

Measurements of Radiation Doses and Risks Estimation During Cardiac Interventional Radiology Procedures

Show simple item record

dc.contributor.author Hamed, Amna Mohammed Khalifa
dc.contributor.author Supervisor, -Abdelmoneim Adam M. Suleiman
dc.contributor.author Co-Supervisor, -Ahmed Elhassan Elfaki
dc.date.accessioned 2019-07-04T08:04:21Z
dc.date.available 2019-07-04T08:04:21Z
dc.date.issued 2019-05-01
dc.identifier.citation Hamed, Amna Mohammed Khalifa . Measurements of Radiation Doses and Risks Estimation During Cardiac Interventional Radiology Procedures \ Amna Mohammed Khalifa Hamed ; Abdelmoneim Adam M. Suleiman .- Khartoum: Sudan University of Science and Technology, College of Science, 2019 .- 109p. :ill. ;28cm .- PhD en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/22808
dc.description Thesis en_US
dc.description.abstract The focus of our study is the measurement of radiation doses and risk assessment during interventional cardiac procedures. When X-rays are used to depict the arteries and veins of the heart for the safety of diagnosis and treatment, the patient is exposed to direct radiation, and when taking high doses, the patient has the risk of radiation. The purpose of this study is to evaluate the optimal dose and to clarify the factors that affect the dose of radiation to which the patient is exposed and how to avoid exceeding the permissible dose limit. 188 Cardiac procedures for elderly patients in two heart centers in Sudan in period (2016 - 2018), we divided the intervention heart procedures into three main groups is coronary angiography, coronary catheterization and pacemaker. We measured the dose area product, and the entrance surface dose. We found that the high dose in the therapeutic catheter is (102.9± 50.7 Gycm2) was higher than the diagnosis is (50.5± 17.9 Gycm2) and less at the pacemaker is (24.6± 1.9 Gycm2). When estimating the risk of radiation, we found that the risk ratio is weak (highest value recorded in the therapeutic catheter (0.3%) and minimum in pacemaker (0.03%)) and does not cause any damage unless repeated exposure to radiation. The study found that the optimal radiation dose depends on a number of parameters of exposure, Fluoroscopy time an number of films and number of frame, and to reduce the risk of radiation and achieve the optimal dose and maintain the lowest possible level, we recommended apply the largest possible distance and minimum number of frame and the number of films and Follow all procedures with high accuracy and train doctors and radiologist as well as suggest a specific program planning before the procedure so this helps to reduce radiation dose and avoid radiation hazards en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Sciences en_US
dc.subject Physics en_US
dc.subject Measurements of Radiation Doses en_US
dc.subject Risks Estimation en_US
dc.subject During Cardiac Interventional Radiology Procedures قياس en_US
dc.title Measurements of Radiation Doses and Risks Estimation During Cardiac Interventional Radiology Procedures en_US
dc.title.alternative قياس الجرعات الإشعاعية وتقدير المخاطر أثناء فحصوات الأشعة التداخلية للقلب en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account