dc.contributor.author |
Mohammed, Dalia Ahmed Gasm El Seed |
|
dc.contributor.author |
Supervisor, -Elhadi Mohieldin Awooda |
|
dc.contributor.author |
Co-Supervisor, -.Ali Abdel Rahman Saeed Marouf |
|
dc.date.accessioned |
2019-06-24T05:33:15Z |
|
dc.date.available |
2019-06-24T05:33:15Z |
|
dc.date.issued |
2018-09-15 |
|
dc.identifier.citation |
Mohammed, Dalia Ahmed Gasm El Seed . Diode laser (808 nm) Versus Rotary Abrasion in the Treatment of Gingival Hyper Pigmentation (Comparative Study) \ Dalia Ahmed Gasm El Seed Mohammed ; Elhadi Mohieldin Awooda .- Khartoum : sudan university of science and technology , Institute Of Laser , 2018.- 60 P. : ill. ; 28cm .- Higher Diploma |
en_US |
dc.identifier.uri |
http://repository.sustech.edu/handle/123456789/22728 |
|
dc.description |
Higher Diploma |
en_US |
dc.description.abstract |
Background: Dark or black colored gingiva is an important esthetic concern.
Gingival depigmentation procedure is a type of perio plastic surgery where the
gingival epithelium is excised with various techniques to lighten the color of the
gingiva. The aim of this study was to compare gingival depigmentation procedure
with conventional rotary technique and diode laser. Method: This comparative
clinical trial study was carried out among twelve patients who attended the
department of periodontology, Khartoum dental teaching hospital and Dafenshy
Dental Clinic complaining of gingival hyperpigmentation. Patients were informed
about the treatment modalities and signs informed written consents to participate
voluntary. Patients were divided into two groups, group one, treated conventionally
first for one jaw and after one week the other jaw was treated by diode laser, while
group two treated by laser first and then after one week by conventional methods.
Gingival depigmentation was done by diamond bur as conventional method and soft
tissue diode laser with 808nm wavelength in continuous mode. The fiber optic tip
diameter was 600mm lased with power of 1.5 w. Post operative complication
(bleeding ,swelling and infection) , the pain perception by using the (VAS), wound
healing ,patients comfort ability and satisfaction had been assessed after both
procedures in interval of three hours , three days and one week. Results: In this
study most of the subjects did not complain of the post operative complications
(swelling, infection and bleeding) after diamond bur and diode laser depigmentation.
There were Statistical significant difference between VAS in diamond bur group and
VAS in diode laser group after 3hours and three days. In gingival depigmentation
with diode laser the subjects complained of moderate pain while the site treated with
diamond bur abrasion only mild pain was felt, although both sites show decreased in
the pain perception by the end of the first week. The gingiva that treated with diode
laser shows delayed in the wound healing but despite this most of the subjects was
very satisfied by the beautiful pink gingival color in comparison with fair pink with
diamond bur abrasion. Conclusion: Despite the diode laser depigmentation was
associated with delayed wound healing and discomfortable for some subjects; most
of the responders were very satisfied about the esthetic results and time preservation
with diode laser therapy more than the conventional abrasion method. |
en_US |
dc.description.sponsorship |
Sudan University of Science and Technology |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
Sudan University of Science and Technology |
en_US |
dc.subject |
Laser |
en_US |
dc.subject |
Laser Applications |
en_US |
dc.subject |
Versus Rotary Abrasion |
en_US |
dc.subject |
Gingival Hyper Pigmentation |
en_US |
dc.title |
Diode laser (808 nm) Versus Rotary Abrasion in the Treatment of Gingival Hyper Pigmentation (Comparative Study) |
en_US |
dc.title.alternative |
لیزر أشباه الموصلات إزاء كشط المكنة الدورانیة في معالجة زیادة تصبغ اللثة ( دراسة مقارنة ) |
en_US |
dc.type |
Thesis |
en_US |