SUST Repository

Estimation of Patients Dose during Paranasal Sinuses Examinations using Computed Tomography

Show simple item record

dc.contributor.author Alsiddig, Fatima Saad Albashir
dc.contributor.author Supervisor, -Asma Ibrahim Ahmed Alamin
dc.date.accessioned 2019-03-20T07:33:09Z
dc.date.available 2019-03-20T07:33:09Z
dc.date.issued 2018-08-05
dc.identifier.citation Alsiddig, Fatima Saad Albashir . Estimation of Patients Dose during Paranasal Sinuses Examinations using Computed Tomography \ Fatima Saad Albashir Alsiddig ; Asma Ibrahim Ahmed Alamin .- Khartoum : Sudan University of Science and Technology , College of Medical Radiologic Science , 2018 .- 77 p. :ill;28cm.- M.Sc en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/22457
dc.description Thesis en_US
dc.description.abstract Using of Computed Tomography in medical diagnosis delivers high radiation dose to patients comparing with other radiological procedures. Lake of optimizing protocols could be increasing the patients radiation dose. The aim of this study to evaluate the radiation dose to patients during paranasal sinuses Computed Tomography Examinations.the data were collected from Ibn EL haitham Diagnostic Center in period from February to August 2018. A total of 50 patients were examined in CT department with Toshiba machine 4 slices. The amount of radiation dose that received from CT scan depends on dose parameters CTDIvol and DLP. The result of the study revealed that the patients dose obtained from CT Para nasal sinuses examinations presented as mean ± standard deviation, were the patients age was 38.38 ±17.16 ,KVP 120.00±ooo, mA100.54±24.94 , exposure2388.07±3205.41,CTDIvol52.7±25.1mGy,DLP 577.1±267.43mGy.cm and ED 8.66±4.0114 mSv . The study concluded that the selection of the most appropriate imaging modality should be performed in view of the delivered doses, required image quality and information and the clinical circumstances en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic Sciences en_US
dc.subject Diagnostic Radiology Technology en_US
dc.subject Patients Dose en_US
dc.subject during Paranasal Sinuses Examinations en_US
dc.title Estimation of Patients Dose during Paranasal Sinuses Examinations using Computed Tomography en_US
dc.title.alternative تقدير الجرعة الإشعاعية للمرضي اثناء اختبارات الجيوب الأنفية بإستخدام التصوير المقطعي en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account