SUST Repository

Establishing Reference Diameters of Abdominal Aortic and Inferior Vena Cava of Sudanese Using Computed Tomography

Show simple item record

dc.contributor.author Ahmad, Salah Elbagir
dc.contributor.author Supervisor, -Mohamed Mohamed Omer Mohamed Yousef
dc.contributor.author Co-Supervisor, -Ikhlas Abdelaziz
dc.date.accessioned 2019-02-03T11:52:58Z
dc.date.available 2019-02-03T11:52:58Z
dc.date.issued 2018-07-03
dc.identifier.citation Ahmad, Salah Elbagir . Establishing Reference Diameters of Abdominal Aortic and Inferior Vena Cava of Sudanese Using Computed Tomography \ Salah Elbagir Ahmad ; Mohamed Mohamed Omer Mohamed Yousef .- Khartoum : Sudan University of Science and Technology , College of Medical Radiologic Science , 2018 .- 104 p. :ill;28cm.- PhD en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/22303
dc.description Thesis en_US
dc.description.abstract Computerized angiography (CTA) is a standard tool for investigating vascular diseases .The aims of this study were to study Reference Diameters of Abdominal Aortic and Inferior Vena Cava of Sudanese Using Computed Tomography and to study the variation in aortic diameters with age and gender. A total of 200 patients (108 males and 92 females) with a mean age of 48.6 years consecutive adults free of cardiac or aortic structural disease or arrhythmia who referred for abdominal CT scanning in the radiology department of Royal Care Hospital in Khartoum- Sudan during the period from August 2015 to May 2018. This study revealed that the mean internal diameters of the suprarenal and infrarenal abdominal aorta were measured at T12 and L3 vertebral levels and tabulated according to various age groups for both men and women. The results revealed that the mean diameter of the suprarenal abdominal aorta, measured at T12 vertebral level was19.44 mm in women and 20.97mm in men. The mean diameters of the infrarenal abdominal aorta, measured at L3 vertebral level were 14.13 mm. in women and 17.34 mm. in men. The mean± standard deviation (SD) of the anteroposterior (AP) diameter of the IVC in men measured was 25.471.69 mm, 24.151.58 in women . The mean± standard deviation (SD) of the transverse (TV) diameters, measured were 14.111.46 mm. in women and 15.31121.49919mm in men. It concluded that normal dimensions abdominal aorta by CT scan was established and correlated with age and gender which is similar to previously published studies, that normal dimensions IVC by CT scan was established and correlated with age and gender, The information provided in this study will allow radiologists to detect and accurately characterize IVC abnormalities to guide clinical decision making and improve patient care. Recognition of IVC processes is essential to pa¬tient treatment. en_US
dc.description.sponsorship Sudan University of Science & Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic Sciences en_US
dc.subject Diagnostic Radiologic en_US
dc.subject Reference Diameters en_US
dc.subject Abdominal Aortic en_US
dc.subject Inferior Vena Cava en_US
dc.title Establishing Reference Diameters of Abdominal Aortic and Inferior Vena Cava of Sudanese Using Computed Tomography en_US
dc.title.alternative تأسيس اقطار مرجعية للشريان الأورطي البطني والوريد الأجوف السفلي للسودانيين باستخدام التصوير المقطعي المحوسب en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account