SUST Repository

Estimation of Exposure Level of Radioactive Waste in Elnileen Medical Diagnostic Center

Show simple item record

dc.contributor.author Alawi, Aymn Salem Zain
dc.contributor.author Supervisor -Mohammed Ahmed Ali Omer
dc.date.accessioned 2013-11-12T14:24:26Z
dc.date.available 2013-11-12T14:24:26Z
dc.date.issued 2011-01-01
dc.identifier.citation Alawi,Aymn Salem Zain. Estimation of Exposure Level of Radioactive Waste in Elnileen Medical Diagnostic Center/Aymn Salem Zain Alawi ; Mohammed Ahmed Ali Omer.- Khartoum : sudan university of science and technology,Medical Radiologic Science,2011.-87p. : ill . ;28cm .-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/2224
dc.description Thesis en_US
dc.description.abstract Many studies have shown that the vulnerability of nuclear medicine technologists to radiation is evident from the radioactive waste. We in this study have drawn upon the existing activities in the nuclear medicine department at the centre of Elnilain for medical diagnosis, where continued study for more than 8 days, and the purpose of this study was to estimate the level of the dose to technologist , nurses and other persons who were present in the hot lab from the Department of Nuclear Medicine during the elution process of the generator of TC-99m, and then compare the results of the dose that subjected them to the standards of the International Radiation Protection (ICRP). In this study, using of survey meter type (Victoreen 451) to measure doses of radiation, and of which we found that the cumulative dose of the hands of technologist approximately 9.4 mSv per year and this dose is less than the limits of dose permitted 500 mSv per year, also found that the dose to technologist 3.6 mSv per year and this is also less than the dose limit with 20 mSv per year, and the dose to the nurse was 1 mSv per year, less than allowed by 20 mSv, the patient also we found that it is exposed to dose of 0.8 mSv and this value concern near to the 8 ‫‪allowed 1 mSv the non-working people(public). And the co- patient exposed‬‬ ‫‪to a dose of 0.3 mSv, and this value is less than the allowable limit 1 mSv for‬‬ ‫‪.public‬‬ en_US
dc.description.sponsorship sudan university of science and Technology en_US
dc.language.iso en en_US
dc.publisher sudan university of science and technology en_US
dc.subject Estimation en_US
dc.subject Diagnostic en_US
dc.title Estimation of Exposure Level of Radioactive Waste in Elnileen Medical Diagnostic Center en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search SUST


Browse

My Account