SUST Repository

Measurement of Radiation Dose In Brain Computed Tomography

Show simple item record

dc.contributor.author Mohammed, Fatima Mohammed Omer
dc.contributor.author Supervisor, -Mona Ahmed Mohammed
dc.date.accessioned 2018-11-28T08:10:30Z
dc.date.available 2018-11-28T08:10:30Z
dc.date.issued 2018-09-27
dc.identifier.citation Mohammed, Fatima Mohammed Omer . Measurement of Radiation Dose In Brain Computed Tomography \ Fatima Mohammed Omer Mohammed ; Mona Ahmed Mohammed .- Khartoum:Sudan University of Science & Technology,College of Medical Radiologic Science,2018.-61p.:ill.;28cm.-M.Sc en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/21917
dc.description Thesis en_US
dc.description.abstract Computed tomography (CT), is an X-ray procedure that generates high quality cross-sectional images of the body, and comparison to other radiological diagnosis, CT is responsible for higher doses to patients. The general objective of this study to measure effective radiation dose of brain and confirm is there any difference between effective dose of male brain and female brain according to differences at anatomical structure of male brain and female brain, then correlation between effective radiation dose and mAs. The data of this study were collected from IBN AL Haitham DIAGNOSTIC CENTER ,Anumber of 60 patients(50% male and 50%female) by used Asteion Toshiab (4 slice) by selected same value of KVP(120). The study showed amount of average effective radiation dose (1.8776 msv) and it's not above from standard effective dose of brain (2 mSv) that recommended by ICRP. Also there is no any difference between effective dose of male brain and female brain according to differences at anatomical structure of brain we found the effective radiation dose of male equal (1.9601 msv) and effective radiation dose of female equal (1.7952 msv) .and proportional relation between effective radiation dose and mAS. en_US
dc.description.sponsorship Sudan University of Science & Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic Sciences en_US
dc.subject Diagnostic Radiologic en_US
dc.subject Radiation Dose en_US
dc.subject Brain Computed Tomography en_US
dc.title Measurement of Radiation Dose In Brain Computed Tomography en_US
dc.title.alternative قياس الجرعة الإشعاعية في التصوير المقطعي للدماغ en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account