Evaluation of Dose Calibrator Performance in Royal Care International Hospital

Show simple item record

dc.contributor.author Mohammed, Faiza Abdelraheem Ali
dc.contributor.author Supervisor, -Awad Abdalla Adlan
dc.date.accessioned 2018-10-11T07:22:28Z
dc.date.available 2018-10-11T07:22:28Z
dc.date.issued 2018-01-11
dc.identifier.citation Mohammed, Faiza Abdelraheem Ali . Evaluation of Dose Calibrator Performance in Royal Care International Hospital \ Faiza Abdelraheem Ali Mohammed ; Awad Abdalla Adlan .- Khartoum:Sudan University of Science & Technology,College of Medical Radiologic Science,2018.-39p.:ill.;28cm.-M.Sc en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/21645
dc.description Thesis en_US
dc.description.abstract This study was conducted to evaluate the performance of the dose calibrators that are used in Royal Care International Hospital (Khartoum State). The study was conducted in the nuclear medicine department in the period from July to November 2017. Quality control tests including precision, linearity, and geometrical dependency were performed using 99mTc source. To check the short term reproducibility of the dose calibrator, a standard source of 99mTc with an activity of (91 mCi) was measured ten times with a mean reading of (90.4 mCi), (±0.294). For determination of linearity 7 readings were made to standard source of 99mTc with activity of (190 mCi) at intervals up to 45 hours Geometric dependence testing was carried out by four syringes with different volumes, using standard source of Tc99m with activity of (2.60 mCi) and measured four times with a mean reading of (2.59 mCi), (±0.005). Results obtained have been compared with the international standard (±5%) and the results showed that the dose calibrator has good performance and there is no need for any correction tables or factors or maintenance for the time being. en_US
dc.description.sponsorship Sudan University of Science & Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic Sciences en_US
dc.subject Medical Physics en_US
dc.subject Care International Hospital en_US
dc.subject Dose Calibrator Performance en_US
dc.title Evaluation of Dose Calibrator Performance in Royal Care International Hospital en_US
dc.title.alternative تقويم أداء معايير الجرعات الإشعاعية بمستشفى رويال كير العالمية en_US
dc.type Thesis en_US