SUST Repository

Applications of Quality Assurance for Tc 99m MAG3 & DMSA in Department of Nuclear Medicine

Show simple item record

dc.contributor.author Abdeen, Mohamed Ahmed
dc.contributor.author Supervisor-Mohammed Elfadiel
dc.date.accessioned 2013-11-10T11:44:10Z
dc.date.available 2013-11-10T11:44:10Z
dc.date.issued 2009-01-01
dc.identifier.citation Abdeen ,Mohamed Ahmed .Applications of Quality Assurance for Tc 99m MAG3 & DMSA in Department of Nuclear Medicine/Mohamed Ahmed Abdeen ; Mohammed Elfadiel.- Khartoum : sudan university of science and technology,Medical Radiologic Science,2009 .- 96p. : ill .;28cm.- M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/2152
dc.description Thesis en_US
dc.description.abstract This prospective study was aimed to assess inter- and intra-operator variability during routine quality control (QC) procedure for technetium-99m (99mTc-MAG3 and DMSA) instant kit formulation. A total of 10 QC analyses with thin layer chromatography (TLC) for 20 separate MAG3 reconstitutions were performed. The percentage of free and hydrolysed 99mTc as well as binding efficiency, were calculated according to standard TLC. Each QC analysis was done using silica gel (SG), silica acrylic (SA), Whatman 1 (W1) and Whatman 3 (W3) TLC strips separately at 1h, following labeling MAG3 instant kit with 99mTc-pertechnetate. To assess the radiochemical stability of 99mTc-MAG3, the same analysis was performed after kit reconstitution. Visual confirmation for QC with scintigraphy was also performed. At both time points, each repeated all the procedure twice for each of the TLC paper types to analyze the intra-operator reliability. Crombach’s Test was used for the reliability analysis. High inter-operator correlation ratios (range: 0.821-0.920) per each TLC strip were found where the highest concordance rate was 0.921 for SA. Each TLC strip showed adequate kit reconstitution with acceptable free and hydrolysed 99mTc percentages in all analyses, along with high binding efficiency values of 94.3 ± 2.9 and 92.5 ± 1.9 at respectively. Intra-observers reliability showed almost equal high concordance rates (range: 0.888-0.961) for all types of strips. In conclusion, all kinds of ITLC/TLC strips were reliable to assess stability of the radiopharmaceutical at 1 and 4 h while analysis with the SA strip had the highest concordance rate. Inter- and intra-operator QC was also reliable. en_US
dc.description.sponsorship sudan university of science and technology en_US
dc.language.iso en en_US
dc.publisher sudan university of science and technology en_US
dc.subject Medicine en_US
dc.subject Nuclear en_US
dc.title Applications of Quality Assurance for Tc 99m MAG3 & DMSA in Department of Nuclear Medicine en_US
dc.type Thesis en_US