SUST Repository

Study of the Scattered X-ray distributions around a Mammographic Unit

Show simple item record

dc.contributor.author Mohamed, Hayfa Mostafa
dc.contributor.author Supervisor, -Ahmed Mostafa Abukonna
dc.date.accessioned 2018-08-01T07:15:32Z
dc.date.available 2018-08-01T07:15:32Z
dc.date.issued 2018-01-25
dc.identifier.citation Mohamed, Hayfa Mostafa . Study of the Scattered X-ray distributions around a Mammographic Unit \ Hayfa Mostafa Mohamed ; Ahmed Mostafa Abukonna .- Khartoum :Sudan University of Science and Technology , Medical Radiologic Science,2018.- 49p : ill ;28 cm .- M.Sc en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/21205
dc.description Thesis en_US
dc.description.abstract Mammography continues to be the primary imaging tool in the detection of early breast cancer. Because of the overall increase in the use of medical ionizing radiation, many patients and their physicians are appropriately concerned about individual radiation dose and specifically concerned about the risks of radiation from mammography. The aim of this study was to investigate scatter radiation intensity around modern digital mammography systems in three hospitals under clinical conditions. The readings were carried out using RADOS (RDS-120 Universal Survey Meter). Scatter radiation was measured at different distance in four areas around the mammography unit; these areas were the control room, Technician office, neighboring offices and Waiting area of mammography room. The distance from the mammogram and the four regions was measured. All measurements were taken in Craniocaudal projection. The result of the study showed that the readings of scattered radiation were detected in control room (0.5μSv/h) and neighboring (0.2 μSv/h) office in hospital A. It was also detected in the neighboring office (0.9 μSv/h) in hospital B, while it was noticed in the waiting area (0.8 μSv/h) in hospital C. These scatter measurements could be used in a shielding calculation and compared with current shielding design criteria to determine whether additional radiation protection or alteration to present shielding was required. en_US
dc.description.sponsorship Sudan University of Science & Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic Sciences en_US
dc.subject Medical Physics en_US
dc.subject Scattered X-ray distributions around en_US
dc.subject Mammographic Unit en_US
dc.title Study of the Scattered X-ray distributions around a Mammographic Unit en_US
dc.title.alternative دراسة توزيع الأشعة السينية المستطارة حول وحدة تصوير الثدي en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account