SUST Repository

Optimization of the MRI Brain Protocol for Multiple Sclerosis.

Show simple item record

dc.contributor.author OMER, MOHANAD ABDALLAH
dc.contributor.author Supervisor, -IKHLAS ABDALAZIZ
dc.date.accessioned 2018-07-24T07:03:22Z
dc.date.available 2018-07-24T07:03:22Z
dc.date.issued 2018-05-27
dc.identifier.citation OMER, MOHANAD ABDALLAH . Optimization of the MRI Brain Protocol for Multiple Sclerosis \ MOHANAD ABDALLAH OMER ; IKHLAS ABDALAZIZ .- Khartoum :Sudan University of Science and Technology , Medical Radiologic Science,2018.-103p : ill ;28 cm .- PhD en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/21166
dc.description Thesis en_US
dc.description.abstract Multiple Sclerosis (MS) is a chronic autoimmune inflammatory disease of the central nervous system, which can be diagnosed by magnetic resonance imaging (MRI). This study is an analytical study, which conducted in many diagnostic centers from May 2015 to Mars 2018, MRI brain scan were done for 64 patients (male 18) and female(46) their age range 17 year to 46 year. Patients known case of multiple sclerosis the aim of this study was to evaluate the of routine MRI brain protocol for MS comparing with modified protocol and advanced protocol. The study used image analysis texture and reveal protocol 3 (3D volume) signal intensity increase with age more than routine protocol (5 mm gap 1) and modified protocol (3mm gap 0) were R2 = o.11 ,0.012 and 0.007 P1,p2 and P3 respectively. T test used to differentiate between protocols T-test (Cl =995%) and (pvalue = 0.05) Resulted about significant different between P1 (routine protocol) and P2 (modified protocol) and the mean of them 38.4 and 52.2 respectively. And also there was a significant different between P1 and P3, The mean between them 38.4 and 69.00 respectively. The study was arrived for more accurate discrimination of signal intensity between different brain tissues. Using texture analysis for each DICOM image, then was used Linear discriminant analysis ,classify feature to brain tissues ,CSF and MS.to differentiate between the classes using LDA accuracy of classification 96.7% and sensitivity for each class is 99.7% ,96.8% and for 92.2% (brain tissues, CSF and MS respectively). This program clearly different between these classes which match the routine protocol. Clearly different in signal intensity between CSF, brain tissues and MS, when using the mean, the higher signal noted for MS. The v results revealed the advanced protocol (3D volume) is the best in diagnose MS and then modified protocol. Patients for follow up, the best sequence to detected new plaque, was the volume T1 with contrast substance. The most patients have MS have vitamin D deficiency 57% have vitamin D deficiency and 42% not having. en_US
dc.description.sponsorship Sudan University of Science & Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic Sciences en_US
dc.subject Diagnostic Radiologic en_US
dc.subject Multiple Sclerosis en_US
dc.subject MRI Brain Protocol en_US
dc.title Optimization of the MRI Brain Protocol for Multiple Sclerosis. en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account