dc.contributor.author |
Soliman, Maisa Abdo Mohamed |
|
dc.contributor.author |
Supervisor, -Hussein Ahmed Hassan |
|
dc.date.accessioned |
2018-04-03T05:06:27Z |
|
dc.date.available |
2018-04-03T05:06:27Z |
|
dc.date.issued |
2018-01-15 |
|
dc.identifier.citation |
Soliman, Maisa Abdo Mohamed . Assessment of the patient dose during lumbosacral joint x-ray examination \ Maisa Abdo Mohamed Soliman ; Hussein Ahmed Hassan .- Khartoum :Sudan University of Science and Technology , Medical Radiologic Science,2018.-50 p : ill ;28 cm .- M.Sc |
en_US |
dc.identifier.uri |
http://repository.sustech.edu/handle/123456789/20630 |
|
dc.description |
Thesis |
en_US |
dc.description.abstract |
The objective of this study is to assess the entrance surface dose(ESD)
received by patients undergoing radiological examinations of
lumbosacral joint was done in two centers new halfa and khartoum state ,
Entrance surface dose (ESD) was determined from exposure settings and
patient information by using CAL Dos soft ware program . A sample of
50 adult patients (37 female,13 male) undergoing lumbo sacral joint X
ray examination in two centers . The mean ESD calculated were
(3.36947) mGy (7.68917) mGy in center A and center B respectively.
for the lumbosacral joint at the ages((20-40),(40-60) and (60-80) years
found to be (2.6076,3.8727 , 4.1110)mGy .incenter B the ESD at the
ages (25-45) and (45-65) years found to be (7.0150 ,8.3633 ) .
For (AP) projection a strong correlation was shown between ESD and
KVp, mAs and patient weight. |
en_US |
dc.description.sponsorship |
Sudan University of Science & Technology |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
Sudan University of Science and Technology |
en_US |
dc.subject |
Medical Radiologic Sciences |
en_US |
dc.subject |
Medical Physics |
en_US |
dc.subject |
patient dose |
en_US |
dc.subject |
lumbosacral joint x-ray examination |
en_US |
dc.title |
Assessment of the patient dose during lumbosacral joint x-ray examination |
en_US |
dc.type |
Thesis |
en_US |