SUST Repository

Detection of Some Elements in Original Kohl Al-Ethmed and Non Original Kohl Al-Ethmed Using X-Ray Fluorescence Device

Show simple item record

dc.contributor.author Suliman, Fatima Mokhtar Ahmed
dc.contributor.author Supervisor, - Rawia Abdelgani Elobaid
dc.date.accessioned 2018-03-18T09:17:53Z
dc.date.available 2018-03-18T09:17:53Z
dc.date.issued 2017-10-21
dc.identifier.citation Suliman, Fatima Mokhtar Ahmed . Detection of Some Elements in Original Kohl Al-Ethmed and Non Original Kohl Al-Ethmed Using X-Ray Fluorescence Device / Fatima Mokhtar Ahmed Suliman ; Rawia Abdelgani Elobaid .- Khartoum: Sudan University of Science and Technology, college of Science, 2017 .- 34p. :ill. ;28cm .- M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/20509
dc.description Thesis en_US
dc.description.abstract Kohl is a traditional powder-like mixture, such as powdered antimony sulfide, used as cosmetic eyeliner and to treat eye diseases in many Middle and Far East countries. This research deals with the applications of spectroscopy, which is the detection of some elements of the original Kohl Al-Ethmed and the non-original Kohl Al-Ethmed and the concentration of these elements by X-Ray Fluorescence device and the comparison between them. Some elements were found in the original Kohl Al-Ethmed; which found chromium element and its concentration 0.00%, manganese element, concentration 27.00%, Iron element and its concentration was 0.28%, nickel element, its concentration 4.00%, copper element, its concentration 0.00%, zinc element, its concentration 0.02 %and lead element and its concentration 20%. In non-original Kohl Al-Ethmed sample there were no elements concentrations except zinc and lead, t zinc element, its concentration 2.9% and lead element and its concentration was 97.9%, so the original kohl Al-Ethmed is better for eye. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Physics en_US
dc.subject X-Ray Fluorescence Device en_US
dc.subject Elements in Original en_US
dc.subject Kohl en_US
dc.title Detection of Some Elements in Original Kohl Al-Ethmed and Non Original Kohl Al-Ethmed Using X-Ray Fluorescence Device en_US
dc.title.alternative الكشف عن بعض العناصر في كحل الأثمد الأصلي وغير الأصلي بواسطة جهاز الأشعة السينية المتوهجة en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account