SUST Repository

Evaluation of Dose Reference Levels for Radiological Procedures in Sudanese Hospitals using (RaySafe Xi) detector

Show simple item record

dc.contributor.author Abdullah, Najla Abdullah Mansour
dc.contributor.author Supervisor, -Ahmed Mostafa Abukonna
dc.date.accessioned 2017-11-06T06:04:04Z
dc.date.available 2017-11-06T06:04:04Z
dc.date.issued 2017-06-05
dc.identifier.citation Abdullah, Najla Abdullah Mansour . Evaluation of Dose Reference Levels for Radiological Procedures in Sudanese Hospitals using (RaySafe Xi) detector \ Najla Abdullah Mansour Abdullah ; Ahmed Mostafa Abukonna .- Khartoum:Sudan University of Science & Technology,Medical Radiologic Sciences,2017.-58p.:ill.;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/18937
dc.description Thesis en_US
dc.description.abstract The DRL is usually set at the third quartile value of the distribution of typical doses derived from those surveys both nationally and internationally. Using the third quartile or 75th percentile is a compromise between being overly stringent and overly complacent. The result of initial proposed DRL was obtained by calculating the entrance surface dose (ESD) for Conventional Radiological examinations. The aim of this study was to evaluate the local diagnostic reference levels (DRLs) in diagnostic radiology departments of some conventional x-ray examinations in Sudan. A total of ten governmental hospitals were assessed by estimating entrance surface dose (ESD) for six radiographic examinations including: skull (AP, LAT), chest (PA, LAT), abdomen (AP), lumbar spines (LAT) and pelvis (AP) exam. The proposed DRLs values were compared with the measured entrance surface doses in different countries and their results were compared with dose levels recommended by relevant organizations. The descriptive were reported. The results obtained in mGy were, 6.0 for the skull (AP), 7.1 for the skull (LAT), 0.9 for chest (PA), 9.2 for abdomen (AP), 18.3 for lumbar spines (LAT) and 8.1 for pelvis (AP). The obtained DRLs can provide a database for future dose measurements and improve the image quality and eventually reducing the dose to the patients. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic Sciences en_US
dc.subject Degree in Medical Physics en_US
dc.subject Radiological Procedures en_US
dc.subject Dose Reference Levels en_US
dc.title Evaluation of Dose Reference Levels for Radiological Procedures in Sudanese Hospitals using (RaySafe Xi) detector en_US
dc.title.alternative تقییم مستویات الجرعة المرجعیة للفحوصات الإشعاعیة في المستشفیات السودانیة باستخدام كاشف en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account