SUST Repository

Study of Nuclear Radiation Counting Systems

Show simple item record

dc.contributor.author Ali, Luai Anwer Ahmed
dc.contributor.author Supervisor, ,- Ahmed ELhassan ELfaki
dc.date.accessioned 2017-09-25T08:30:26Z
dc.date.available 2017-09-25T08:30:26Z
dc.date.issued 2017-05-10
dc.identifier.citation Ali, Luai Anwer Ahmed . Study of Nuclear Radiation Counting Systems / Luai Anwer Ahmed Ali ; Ahmed ELhassan ELfaki .- Khartoum: Sudan University of Science and Technology, college of Science, 2017 .- 45 p. :ill. ;28cm .- M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/18580
dc.description Thesis en_US
dc.description.abstract Nuclear radiation counting systems are used for measuring the nuclear radiation, depending on the application the counting systems can be roughly grouped into Single channel analyzer (SCA) systems and Multi-channel analyzer (MCA) systems. The measurement of radiation is distinguished into two categories. The first category is measuring the number of radiations or intensity which depends on the activity of the source of radiation. The second category is measuring the energy distribution of incoming radiation which is characteristic to the type of the source of radiation. The number of output pulses from detector is proportional to the number of incoming radiation so the intensity of radiation can be measured just by counting those electric pulses which are produced by the detector. The single channel analyzer system is used to carry out intensity measurements by using threshold window (one energy range only). On the other hand the spectrum of radiation can give information about the intensity at each energy level or energy peaks of the incoming radiation. The multi-channel analyzer is used to carry out energy distribution spectrum measurements. In terms of internal functioning, multi-channel analyzer is different from single channel analyzer. The multi-channel analyzer performs the same task with many of threshold windows, thus it doesn’t need to count pulses at each threshold window individually, therefore making the process faster. en_US
dc.description.sponsorship Sudan University of Sciences and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Sciences and Technology en_US
dc.subject Nuclear physics en_US
dc.subject Radiation Counting Systems en_US
dc.title Study of Nuclear Radiation Counting Systems en_US
dc.title.alternative دراسة أنظمة العد الإشعاعي النووي en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account