SUST Repository

Comparison of Complete Blood Count Using Digon Dcell60, Sysmex kxn-21 and URIT 3010 Haematological Analyzers

Show simple item record

dc.contributor.author Nassir, Hana Salah Abd Alla
dc.date.accessioned 2017-06-15T08:31:50Z
dc.date.available 2017-06-15T08:31:50Z
dc.date.issued 2017-04-24
dc.identifier.citation Nassir, Hana Salah Abd Alla . Comparison of Complete Blood Count Using Digon Dcell60, Sysmex kxn-21 and URIT 3010 Haematological Analyzers \ Hana Salah Abd Alla Nassir ; KhaldaMergani Hamza .- Khartoum:Sudan University of Science & Technology,Medical Laboratory Science,2017.-59 p.:ill.;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/18005
dc.description Thesis en_US
dc.description.abstract This was a prospective and cross sectional study conducted in Hi Tech Laboratory, Dr. Mohammed Altaib Laboratory and Modern Medical Laboratory during the period from February to August 2016 .The study was performed to determine the complete blood count using three different Automated hematology analyzers and aimed to compare between this machines, fifty blood samples were collected in EDTA container (2.5ml) , CBC estimation was carried by sysmex kxn-21, Digon D cell-60 and URIT 3010 hematological analyzers and the results were analyzed using Statistical package for Social Science computer program, Mean ± SD and One way Anova test were used (p.value >0.05) ,Sensitivity and Specificity also were measured. The results indicated that there was significant correlation in the mean of Hb, RBC, HCT, MCV, MCHC, RDW-CV , WBCs ,Neutrophil ,MIX (monocyte ,eosinophil ,basophil ), MPV ,PDW and PLCR P. value <0.05 , while there was insignificant correlation in means of MCH ,RDW-CV ,Lymphocyte and PLT P. value ≥0.05. Sysmex kxn-21 hematological analyzer found to be more sensitive and specific when using in measurement of Hb , RBC, HCT ,MCV, MCHC, RDW-SD compared with Digon D cell-60 and URIT 3010 hematological analyzers ,while URIT 3010 hematological analyzer was more sensitive and specific when using in measurement of WBCs, Lymphocyte, Neutrophil ,MIX count, PLT, MPV,PDW compared with them. The study concluded that both Sysmex kxn-21 and URIT 3010 hematological analyzers were more sensitive and specific in measurement of CBC. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Laboratory Science en_US
dc.subject Hematology and Immunohematology en_US
dc.subject Complete Blood Count en_US
dc.subject Haematological Analyzers en_US
dc.title Comparison of Complete Blood Count Using Digon Dcell60, Sysmex kxn-21 and URIT 3010 Haematological Analyzers en_US
dc.type Thesis en_US
dc.contributor.Supervisor Supervisor,- Khalda Mergani Hamza


Files in this item