Evaluation Of Image Quality For Emergency Traumatic Patients

Show simple item record

dc.contributor.author ELGORAESH, SIDDIG ADAM BABIKIR
dc.date.accessioned 2017-04-27T07:40:00Z
dc.date.available 2017-04-27T07:40:00Z
dc.date.issued 2016-03-15
dc.identifier.citation ELGORAESH, SIDDIG ADAM BABIKIR . Evaluation Of Image Quality For Emergency Traumatic Patients \ SIDDIG ADAM BABIKIR ELGORAESH ; MOHAMED MOHAMED OMER M.YOUSEF .- Khartoum:Sudan University of Sciences and Technology,Medical Radiographic Sciences,2016.-63p:ill;28cm.- M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/16801
dc.description Thesis en_US
dc.description.abstract Objective: is to apply a technical protocol to reduce CT radiation Dose in trauma cases by decreasing the mA (tube current). The target reduction is 50%. Method: Performing scanning on an adult phantom for trauma protocol Brain. Reference scan (default exposure) 300mA to be registered In exposure log shoot and calculate the dose received in msv. Scan2 reducing mA to200 and registered the dose, evaluate the Image quality.scan 3 reducing mA to100 and registered the dose Received, evaluate the image .phase (2)implemented if phantom Image quality is of acceptable quality .Performing CT trauma with The default exposure parameters and register the dose received . Reference scan can be obtained from previous CT trauma cases. Performing CT trauma with reduction of mA factor to 200mA and Registering the dose received image to be evaluated by the tech- -nologist and radiologist. Performing CT trauma with reduction of mA factor to 100mA and register the dose received .Image also to be evaluated by the technologist and radiologist .Applying the rec- -commendations CT technologists and radiologists on the range of Accepted quality and delineate the reduction rate. CT trauma cases with reduced mA can be viewed and the review The radiologist reports . Reduction of mA factor in CT parameters will induce reduction in CT dose to the patient and this can be applied to all cases. Performed scan for 54 cases 28 cases with tube current 200 mA And 26 cases with tube current 100 mA .The result was found Clearly the absorbed dose and the effective dose fall down to the Half when used 200mA and more less when we used 100mA as tube current . en_US
dc.description.sponsorship Sudan University of Sciences and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic Sciences en_US
dc.subject Diagnostic Radiologic Technology en_US
dc.subject Image Quality en_US
dc.subject Emergency Traumatic Patients en_US
dc.title Evaluation Of Image Quality For Emergency Traumatic Patients en_US
dc.title.alternative تقييم جودة صور الأشعة لمرضى اصابات الطواري en_US
dc.type Thesis en_US
dc.contributor.Supervisor Supervisor,- YOUSEF, MOHAMED MOHAMED OMER M.