SUST Repository

Measurement of Normal Diameter of Thoracic Aorta using Computed Tomography

Show simple item record

dc.contributor.author Saad, Amgad Yousif Babiker
dc.date.accessioned 2017-04-18T05:52:40Z
dc.date.available 2017-04-18T05:52:40Z
dc.date.issued 2017-02-09
dc.identifier.citation Saad, Amgad Yousif Babiker . Measurement of Normal Diameter of Thoracic Aorta using Computed Tomography \ Amgad Yousif Babiker Saad ; Asma Ibrahim Ahmed Elameen .- Khartoum:Sudan University of Science & Technology,Medical Radiographic Sciences,2017.-70p.:ill.;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/16121
dc.description Thesis en_US
dc.description.abstract This is a cross sectional descriptive study, deals with measurement of normal diameter of the thoracic aorta in Sudanese population. The study conducted at computed tomography departments of Alribat National hospital , Alamal National hospital diagnostic center and Doctor’s spthalized hospital. A 50 cases were selected randomly, The patients are not suffering from any pathological condition concerning the thoracic aorta. This study used the tools of computed tomography to measure the normal diameter of the descending thoracic aorta. The data designed to include the specific variables for the patients and were analyzed by SPSS program. The mean Length of the thoracic Aorta was 14.71±2.67 cm, The Proximal width of Aorta was 2.51±0.56 cm, the middle width of Aorta was 2.08±0.41 cm, the distal width of Aorta was 2.11±0.45 cm. The height and weight of the patient has showed no significant difference with the aorta diameter than the other variable (p-value is 0.000) respectively. Also highly significant difference (P=0.001) was detected between age and distal width of aorta, but low significant difference (P=0.018) was obtained between the height of the patient and distal width of Aorta. Also lower significant difference (P=0.015) was noticed between weight of the patient and distal width of Aorta. the study concluded that computed tomography is play a great role in the measurement of normal diameter of descending of thoracic aorta en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic Sciences en_US
dc.subject Diagnostic Radiologic Technology en_US
dc.subject Normal Diameter en_US
dc.subject Thoracic Aorta en_US
dc.title Measurement of Normal Diameter of Thoracic Aorta using Computed Tomography en_US
dc.title.alternative قياس الشريان الأبهر الصدري للسودانيين بإستخدام الأشعة المقطعية المحوسبة en_US
dc.type Thesis en_US
dc.contributor.Supervisor Supervisor,- Asma Ibrahim Ahmed Elameen


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account