SUST Repository

Determination of Prothrombin Time and Activated partial Thromboplastin Time by using the same semi-automated device in different laboratories

Show simple item record

dc.contributor.author Abubakir, Samreen Mohammed Fadal
dc.contributor.author Supervisor, - Babiker Ahmed Mohamed
dc.date.accessioned 2017-04-10T09:22:47Z
dc.date.available 2017-04-10T09:22:47Z
dc.date.issued 2016-06-19
dc.identifier.citation Abubakir, Samreen Mohammed Fadal.Determination of Prothrombin Time and Activated partial Thromboplastin Time by using the same semi-automated device in different laboratories/Samreen Mohammed Fadal Abubakir;Babiker Ahmed Mohamed.-Khartoum:Sudan University of Science & Technology;Medical Laboratory Science,2016.-79p.:ill.;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/16047
dc.description Thesis en_US
dc.description.abstract This is across sectional study, conducted in Khartoum state during the period from August to October 2015to compare between PT (prothrombin time) and PTT(activated partial thromboplastin time) that obtained from the same sample by using same semi-automated devices (STAGO) in different lab ,each devices had a different quality control sample test, device (1) preformed commercial control ,device (2)preformed pool plasma , of one Hundred (100) Sudanese patients were informed about the study and agreed for participation as case and were entered in the tow study . Three ml venous blood was collected in Tri sodium citrate anticoagulant container. All blood samples were run in calibrated and close control two Same semi-automated devices(STAGO) which are found in two different laboratory, it used to measure PT and PTT and the results were analyzed by one T- test of the SPSS computer programmer. The means were found as following: PT (22.76 seconds), PTT (40.23 seconds).This study was concluded that: There was no significant difference (P = 0.783) in mean of PT (prothrombin time)in device (1) from device (2) and also There was no significant difference (P = 0.498) in mean of PTT (activated partial thromboplastin time)in device (1) from device (2). en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science & Technology en_US
dc.subject Prothrombin Time en_US
dc.subject Thromboplastin Time en_US
dc.title Determination of Prothrombin Time and Activated partial Thromboplastin Time by using the same semi-automated device in different laboratories en_US
dc.title.alternative قياس عوامل التجلط بإستخدام جهاز قياس التجلط ستاغو بمعملين مختلفين فى ولايه الخرطوم en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account