Estimation of Radiation Dose to Eye Lens for the Patients Undergoing Scan of Brain by Computed Tomography

Show simple item record

dc.contributor.author Mohammed, Waleed Elatta Mahmoud
dc.contributor.author Supervisor, - Mohamed Elfadil Mohamed Gar Elnabi
dc.date.accessioned 2017-03-19T11:48:24Z
dc.date.available 2017-03-19T11:48:24Z
dc.date.issued 2017-02-27
dc.identifier.citation Mohammed, Waleed Elatta Mahmoud . Estimation of Radiation Dose to Eye Lens for the Patients Undergoing Scan of Brain by Computed Tomography \ Waleed Elatta Mahmoud Mohammed ; Mohamed Elfadil Mohamed Gar Elnabi .- Kartoum:Sudan University of Science and Technology,Medical Radiologic Sciences,2017 .- 48p:ill;28cm.-M.Sc en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/15799
dc.description Thesis en_US
dc.description.abstract The aim of this study to estimation the radiation dose for eye lens for patients underwent thescan head by CT model of Toshiba 64 slices in the (RCIH,ANH and ZSH). The data collected from 51patient in three hospitals, Data were used to estimation and comparing the Equivalent dose of eye lens from different diagnostic procedures in three hospitals with the other study from deferent country. was used CT-Exposoftware Version 2.5 for dose calculations, the effective dose between the all hospital in this study, the small value of Effective dose in RCIH (3.92 mSv) then ANH (4.64 mSv) and higher dose in ZSH (5.34 mSv) and higher than the study in Tanzania (2.1 mSv), Australia (3.61 mSv) and UK (1.5 mSv), the Equivalent dose of eye lens is small dose in RCIH (82.97 mSv), then ANH (88.61 mSv) and higher dose in ZSH (97.01 mSv), Themean CTDIVOL values in hospitals is higher than similar study in other country example as (UK (55-65 mGy), Sudan (65.4 mGy) and Tanzania (43 mGy)), except the Australia (86.7 mGy), DLP values was found in this study were higher (1547.5 mGy*cm) than those presentedin Tanzania (913 mGy*cm), Australia (1508.4 mGy*cm) and UK (760-930 mGy*cm). en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic Sciences en_US
dc.subject Radiation Dose en_US
dc.subject Eye Lens en_US
dc.subject Computed Tomography en_US
dc.title Estimation of Radiation Dose to Eye Lens for the Patients Undergoing Scan of Brain by Computed Tomography en_US
dc.title.alternative تقدير الجرعة الإشعاعية لعدسة العين للمرضى الذين يخضعون لتصويرالدماغ عن طريق التصوير المقطعي en_US