SUST Repository

Measurement of Portal Vein Diameter in Sudanese Population Using Computed Tomography

Show simple item record

dc.contributor.author Elfaki, Sara Ali Mohammed
dc.contributor.author Supervisor,- Ahmed Mostafa Abukonna
dc.date.accessioned 2017-03-14T07:28:00Z
dc.date.available 2017-03-14T07:28:00Z
dc.date.issued 2017-01-12
dc.identifier.citation Elfaki, Sara Ali Mohammed . Measurement of Portal Vein Diameter in Sudanese Population Using Computed Tomography \ Sara Ali Mohammed Elfaki ; Ahmed Mostafa Abukonna .- Kartoum:Sudan University of Science and Technology,Medical Radiologic Sciences,2017.-57p:ill;28cm.-M.Sc en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/15745
dc.description Thesis en_US
dc.description.abstract The aim of this study was to find out the mean portal vein in Sudanese population using computed tomography. Number of 50 abdominal CT was performed for Sudanese patient in Khartoum state aged between 18-65 years, 24 female and 26 male, with CT machine –Philips 64 slice. Portal vein was measured precontrast and after injection of contrast media. The results of the study revealed that the mean diameter of main portal vein was [14.99 ±0.99] mm in non-contrast image and [15.74 ±0.98] in post contrast images. The minimum diameter in non-contrast image [13.2 mm], in post contrast image [13.6 mm], and maximum diameter in non-contrast image [17.1 mm], in post contrast image [17.8 mm].Furthermore there was strong correlation between main portal vein diameter and age, as age increased the portal vein diameter increased. The mean portal vein diameter for male [16.05±1.05] mm, is slightly higher than mean diameter for female [15.40 ± 0.81] mm. The liver length and width are increased as age increased; there was no relation between liver size and portal vein diameter. Normal mean portal vein diameter measured on CT was significantly larger (mean 15.74 mm) than the accepted upper limit of 13 mm in the literature as measured by other imaging modalities (ultrasound). Sex, age, height, and body mass index significantly affected main portal vein diameter. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic Sciences en_US
dc.subject Diagnostic Radiologic en_US
dc.subject Portal Vein Diameter en_US
dc.subject Using Computed Tomography en_US
dc.title Measurement of Portal Vein Diameter in Sudanese Population Using Computed Tomography en_US
dc.title.alternative قياس قطر الوريد البابي لدي السودانيين باستخدام الأشعة المقطعية المحوسبة en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Share

Search SUST


Browse

My Account