Accuracy of Image Diagnosis by Radiology Technologist for Cranial Computed Tomography

Show simple item record

dc.contributor.author Mustafa, Omar Osman Mohammed Ahmed
dc.contributor.author Supervisor, - Ikhlas Abdelaziz Hassan Mohamed
dc.date.accessioned 2017-01-30T08:27:02Z
dc.date.available 2017-01-30T08:27:02Z
dc.date.issued 2016-11-01
dc.identifier.citation Mustafa, Omar Osman Mohammed Ahmed . Accuracy of Image Diagnosis by Radiology Technologist for Cranial Computed Tomography \ Omar Osman Mohammed Ahmed Mustafa ; Ikhlas Abdelaziz Hassan Mohamed .- khartoum:Sudan University of Science and Technology,college of medical Radiology,2016.-63p. : ill.;28cm.-M.Sc en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/15412
dc.description Thesis en_US
dc.description.abstract Cranial computed tomography (CT) is replacing skull radiography in head trauma. Rapid diagnostic radiological opinions on these images may not always be available. The aim of this study was to determine the accuracy of radiology technologist image diagnosis in different cranial CT cases. A retrospective series of 30 cases was reviewed and interpreted by 20 radiology technologists, and the results compared with the diagnosis of radiologist as reference standard opinion. An overall accuracy of 77.34% was achieved, with a sensitivity of (95.89%) and specificity of (59.74%). The study also found that the accuracy affected by work experience period and peripheral image interpretation courses taken by the technologist. The results are not similar to studies of interpretation of other countries because of different style of education and job description for technologist. The study recommends that more formal educational subjects and courses in image interpretation for technologists and Appropriate training program. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic en_US
dc.subject Cranial Computed Tomography en_US
dc.subject Ultrasongraphy en_US
dc.subject Radiology Technologist en_US
dc.title Accuracy of Image Diagnosis by Radiology Technologist for Cranial Computed Tomography en_US
dc.title.alternative دقة تشخيص الصور بواسطة تقني الأشعة للأشعة المقطعية القحفية en_US
dc.type Thesis en_US