Abstract:
Acne scarring, is a common dermatologic condition. Effective treatment of
facial acne scarring presents a major challenge.
Nonablative laser irradiation has been introduced as a safer modality for the
correction of acne scars, especially in patients with darker skin. Photothermal
effect causing damage to the upper dermis, and initiating wound healing
process leading to collagen synthesis, which improve the atrophic scars.
Study objectives:
1- This study aimed to evaluate the effectiveness of the neodymium:yttriumaluminum-
gamet (Nd: Y AG) laser in treating acne scars in dark skin patients
Materials and Methods:
This study is a prospective, clinical descriptive, interventional study, done in
Sudan University of Science and Technology Institute Of laser, in
collaboration with Alyaa Medical Centre, during the period between
1/2/2011 - 15/4/ 2011. Six patients were included in this study, only five of
them received two treatments with Nd: Y AG laser I 064nm at 3 weeks
interval. The laser parameters used were:
Flounce 70 J/cm2, Spot size: 7 mm, Pulse duration: 70.5 ms, which
fractionated into 3pulses: 3X (7.5 ms for each) with 24 ms delay, Repetition
rate: 1 H.z, cooling spray was used 200 ms before and after the laser
radiation.
Before and after photographs were depicted. A written informed consent
was signed, and laser safety precautions were followed. Three elements for
response evaluation were considered, they are Photograph Analysis, patient
satisfaction and side effects evaluation.
Results and Discussion:
After two treatments, result was excellent in 2 patients ( 40%) and good in
the remaining 3 patients (60%). Four patients (80.0%) experienced mild side
effects as crustation and blistering. Transient hyperpigmentation and/or
hypopigmentation were seen in some of them. No patient experienced
moderate or severe side effects. All patients reported > ( 60%) satisfaction
Conclusion and Recommendation:
The usage of long pulsed 1064 nm Nd: Y AG laser is effective in treating
atrophic acne scars in dark skin patients. After only 2 treatments the result
was excellent in ( 40.0%) of patients and good in ( 60.0% ). All patients were
satisfied by the result, and the side effects were mild and transient
The advisable parameters are 70 J/cm2, 70.5 ms duration with fractionated
pulse: 3X (7.5 ms for each)+ 24 ms delay, 7 mm spot size, and Repetition rate: 1 H.z.