dc.contributor.author |
Yousif, Yousif Hamza |
|
dc.contributor.author |
Supervisor -Abdlmonem
Adam Mohamed |
|
dc.date.accessioned |
2013-09-12T09:04:55Z |
|
dc.date.available |
2013-09-12T09:04:55Z |
|
dc.date.issued |
2013-03-01 |
|
dc.identifier.citation |
Yousif,Yousif Hamza.Estimation of Patient Effective Radiation Dose in Renal System Imaging/Yousif HamzaYousif;Abdlmonem Adam Mohamed .- khartoum : sudan university of scince and technology,Medical Radiologic Science,2013 .- 71p : ill ;28cm .- M.Sc. |
en_US |
dc.identifier.uri |
http://repository.sustech.edu/handle/123456789/1529 |
|
dc.description |
Thesis |
en_US |
dc.description.abstract |
Imaging of the renal system is done with different techniques depending
mainly on clinical symptoms and signs , Renal Scintigraphy and Urography
provides the radiologist with useful detailed information. However, it is whom
responsibility to determine scanning technique factor that provide balance
between image quality and radiation dose and share in keeping patient
radiation exposure at lowest as possible. This study was intended to evaluate
patient radiation dose for nuclear medicine DTPA renal scan , computed
tomography (CT) and conventional urography. This study was conducted at
Alnilain Diagnostic Center, Khartoum during 3months.
Machine used for renal scan was Orbiter 37 Gamma camera single head
37PMTs/ FOV 387mm , CT machine, SIEMENS-SOMATOM emotion duo
for CTU, and SHIMADZU, permanent filtration 1.5 mm AL at 70 kV for
IVU. Effective doses was estimated using a conversion factors based on
Monte Carlo Simulation. Patients’ radiation dose value for DTPA renal scan
was (0.78 ±0.18 mSv) , Patients’ radiation dose values for CTU were 168.6
±62.6 mGy/cm (DLP), and Effective dose 2.53± 0.94 mSv
Patients radiation dose values for IVU were 21.62±5.85 mGy ESD and
1.79±0.48 mSv Effective dose . |
en_US |
dc.description.sponsorship |
sudan university of science and technology |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
sudan university of scince and technology |
en_US |
dc.subject |
Renal system |
en_US |
dc.subject |
imaging |
en_US |
dc.title |
Estimation of Patient Effective Radiation Dose in Renal System Imaging |
en_US |
dc.type |
Thesis |
en_US |