SUST Repository

Estimation of Entrance skin doseESD for pediatric X-ray examination for limbs

Show simple item record

dc.contributor.author Mansour, Wamda
dc.contributor.author Supervisor, - Hussein Ahmad Hassan
dc.date.accessioned 2016-10-27T07:20:48Z
dc.date.available 2016-10-27T07:20:48Z
dc.date.issued 2016-03-23
dc.identifier.citation Mansour, Wamda . Estimation of Entrance skin doseESD for pediatric X-ray examination for limbs \ Wamda Mansour ;Hussein Ahmad Hassan .- Khartoum:Sudan University of Science and Technology,College of Medical Radiologic Sciences,2016.-46p:ill;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/14445
dc.description Thesis en_US
dc.description.abstract This Study was performed to evaluate radiation Entrance skin dose ESD for pediatric patients undergoing X-ray examination for limbs imaging, in two selected centers in Khartoum state which use Computed Radiography (CR) unit. The exposure parameters (kV, mAs and FSD) were chosen for each age category of pediatric from 0-15 years , then the ESD was calculated -by using the Microsoft excel - for each category in the two hospitals and compared with the reference dose level and some previous studies. In center A the ESD for the upper limbs at the ages ((5-10), (11-15)) years found to be(39.24,54.18)µGy and the ESD for the lower limps was (40.3,53.8)µGy and In center B the ESD for the upper limbsat the ages ((5-10), (11-15)) years was (43.7, 61.07) µGy and the ESD for the lower limbs was (45.85,57.6)µGy. The final results showed that The ESD depends and changes with the exposure parameters (KV &mAs) and changes with age.The ESD for the lower limbs was greater than the upper limbs in each center. The ESD in the two centers is within the reference level and lower than the previous studies, also Variations were observed in ESD values among hospitals under study. From this study we recommended that for all x-ray equipment should be regular maintenance and quality control tests and to standardize the exposure parameters in pediatric imaging. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic en_US
dc.subject Entrance skin dose en_US
dc.subject pediatric X-ray examination en_US
dc.title Estimation of Entrance skin doseESD for pediatric X-ray examination for limbs en_US
dc.title.alternative تقدير الجرعة الداخلة للجلد للأطفال عند التصوير الإشعاعي للأطراف en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search SUST


Browse

My Account