SUST Repository

Assessment of Radiation Dose for Patients Undergoing Brain and Abdomen Computed Tomography

Show simple item record

dc.contributor.author OSMAN, NAIF MOHAMMED
dc.contributor.author Supervisor, - AHMED ALMUSTAFA ABOKONNA
dc.date.accessioned 2016-10-23T08:02:35Z
dc.date.available 2016-10-23T08:02:35Z
dc.date.issued 2016-06-10
dc.identifier.citation OSMAN, NAIF MOHAMMED . Assessment of Radiation Dose for Patients Undergoing Brain and Abdomen Computed Tomography \ NAIF MOHAMMED OSMAN ; AHMED ALMUSTAFA ABOKONNA .- Khartoum:Sudan University of Science and Technology,College of Medical Radiologic Sciences,2016.-68p:ill;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/14329
dc.description Thesis en_US
dc.description.abstract Computed tomography (CT) is an imaging technique which produces a digital topographic image from diagnostic x-ray. It always considered a “high dose” technique, there is growing realization that image quality in CT often exceeds the level needed for confident diagnosis and that patient doses are higher than necessary. The aim of this study was to evaluate the level of radiation dose received by the patients during brain and abdomen CT examination. In this study, a total of 128 adult patients undergoing brain and the abdominal CT scanning exams were evaluatedusing CT Dose index and dose length product (DLP) The result of this study revealed that the mean effective dose for abdomen in hospital (1) and hospital (2) was(64.31 ± 29.8)mSv and (71.61 ± 0.97) mSvrespectively. The mean effective dose for brain in hospital (1) and hospital (2) was (2.96 ± 0.97)mSv, (3.11±0.51)mSv respectively. These values were found to be at standard dose reference level. Unjustified screening the Abdomen and head should thus be banished. Such policy is unacceptable in young patients who are at a low risk of having an incidental associated disease. Similarity, repeated acquisition should not be performed in circumstances where they do not specifically yield additional information. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Medical Radiologic en_US
dc.subject Radiation Dose for Patients en_US
dc.subject Brain and Abdomen en_US
dc.subject Computed Tomography en_US
dc.title Assessment of Radiation Dose for Patients Undergoing Brain and Abdomen Computed Tomography en_US
dc.title.alternative تقييم جرعة الاشعة للمريض اثناء فحوصات الدماغ والبطن بالاشعة المقطعية المحوسبة en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search SUST


Browse

My Account