SUST Repository

Assessment of Radiation Dose Received By Patient During CT urography

Show simple item record

dc.contributor.author Omar, Aesha Malik Bashir
dc.contributor.author Supervisor,- Hussein Ahmed Hassan
dc.date.accessioned 2016-10-19T08:05:43Z
dc.date.available 2016-10-19T08:05:43Z
dc.date.issued 2016-05-04
dc.identifier.citation Omar, Aesha Malik Bashir.Assessment of Radiation Dose Received By Patient During CT urography/Aesha Malik Bashir Omar;Hussein Ahmed Hassan.-Khartoum:Sudan University of Science & Technology,College of Medical Radiologic Sciences,2016.-89p:ill;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/14299
dc.description Thesis en_US
dc.description.abstract Radiography has major role of diagnostic method in medical field. Urography provides the radiologist with useful detailed information. However, it is the responsibility of radiologist and technologist to determine scanning technique factor that provide balance between image quality and radiation dose and share in keeping patient radiation exposure at lowest as possible. The objective of this study to assess radiation dose from CT and estimate radiation risk for patient during CTU.The patient radiation dose value from this study 3647.81±950.34mGy/cm (DLP), 69.47±14.81mGy(CTDIvol), Effective dose54.72±14.26mSv and cancer probability per million(28.03) ureters and (27.05)for testiles. Radiation dose can vary considerably between scanner and between institutions. Clinical dose are reported as the dose to standard dosimetry phantom. However due to large variation in patient size these dose may not estimate accurately the deliver to patient during a particular exam.In this study the radiation dose isconsidered high compared with previous studies, this may be due to scanner, or protocol used. A patient radiation risk for particular exam is proportional to the dose delivered during exam. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science & Technology en_US
dc.subject Medical Radiologic Science en_US
dc.subject Radiation Dose en_US
dc.subject During CT en_US
dc.subject urography en_US
dc.title Assessment of Radiation Dose Received By Patient During CT urography en_US
dc.title.alternative تقويم الجرعة الاشعاعيه للمريض اثناء تصوير الجهاز البولى بالاشعة المقطعية en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search SUST


Browse

My Account