dc.contributor.author |
Idris, Fathalla Mohamed Ahmed |
|
dc.contributor.author |
Supervisor, Mubarak Dirar Abd-Alla |
|
dc.date.accessioned |
2016-09-27T09:36:33Z |
|
dc.date.available |
2016-09-27T09:36:33Z |
|
dc.date.issued |
2016-03-10 |
|
dc.identifier.citation |
Idris, Fathalla Mohamed Ahmed . A Study on the Variation of Radiation Intensity of Telecommunication Tower Horizontal and Vertical Dimensions / Fathalla Mohamed Ahmed Idris ; Mubarak Dirar Abd-Alla .- Khartoum: Sudan University of Science and Technology, college of Science, 2016 .- 124p. :ill. ;28cm .-PhD. |
en_US |
dc.identifier.uri |
http://repository.sustech.edu/handle/123456789/14212 |
|
dc.description |
Thesis |
en_US |
dc.description.abstract |
Electromagnetic radiation is a form of energy emitted and absorbed by
charged particles; electromagnetic radiation is characterized by its
biological effects on human cells. Mobile phone towers which emit
electromagnetic radiation are intensively distributed in cities and towns.
This requires studying their biological hazards.
The study was designed and conducted on the basis of selection of the
three major telecommunication companies towers in Sudan, namely
ZAIN, SUDANI and MTN. Three different geographical locations were
also selected including Khartoum state, red sea state and river Nile state.
Number of (120) towers from each company was randomly selected in
each of the three previously mentioned States (40towers for each
company in particular state) for this study. The levels of the
electromagnetic radiation emitted by hese towers were measured at
different distances (5m ,10m , 15m , 20m ,25m, 30m) using the
radiometer measurement . The results obtained indicated that increase in
the horizontal distance from the tower is associated with gradual decrease
in the electromagnetic radiation levels. This decrease of intensity with
distance conforms to the theoretical relation. It was also observed that the
height of towers affect the radiation intensity, where the radiation
intensity increases as the height increases. This relation also agrees with
the theoretical relation. Also the results obtained showed that the
electromagnetic radiation levels measured from towers belonging to
SUDANI Company is higher than those from towers of ZAIN and MTN
companies in each state. However all electromagnetic radiation levels are
still safe and within the permissible range of international allowed doses.
It was also noted that electromagnetic radiation level measured from all
V
these towers collectively are higher in Khartoum state as compared to red
sea and river Nile state.
This might possibly be attributed to the higher number of these towers
distributed in Khartoum state as compared to other states.
Generally, the measurements employed showed that the level of
electromagnetic radiation is not that significant and still safe with
reference to the recommendation of world health organization (WHO)
and international telecommunication corporation (ITC). Therefore a nonadverse
obvious effect on the biological system is expected.However a
ware should be taken for the long exposure time for these low doses.
This study highlighted the levels and effects of the electromagnetic
radiation emitted by the towers in three states, thus, we recommend
another future study should be carried out to include more states and
other sources of electromagnetic radiation emissions, etc. cell phones,
electricity lines and other electronic devices. |
en_US |
dc.description.sponsorship |
Sudan University of Science and Technology |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
Sudan University of Science and Technology |
en_US |
dc.subject |
Physics Science |
en_US |
dc.subject |
D Rissah a change |
en_US |
dc.subject |
Radiation |
en_US |
dc.subject |
Communications Tower |
en_US |
dc.subject |
Dimensions The horizontal and a moored |
en_US |
dc.title |
A Study on the Variation of Radiation Intensity of Telecommunication Tower Horizontal and Vertical Dimensions |
en_US |
dc.title.alternative |
د ا رسة التغير في شدة الإشعاع الصادر من برج الاتصالات مع الأبعاد الأفقية و ال أ رسية |
en_US |
dc.type |
Thesis |
en_US |