SUST Repository

Evaluation of Using Fourier Infrared Spectroscopy and Laser - Raman in Bladder Malignancy Diagnosis

Show simple item record

dc.contributor.author Ali, Essam Eigeily A/tined
dc.contributor.author Supervisor,-Nafie Abd Allattief Almuslet
dc.date.accessioned 2016-08-31T06:23:30Z
dc.date.available 2016-08-31T06:23:30Z
dc.date.issued 2009-03-03
dc.identifier.citation Ali, Essam Eigeily A/tined . Evaluation of Using Fourier Infrared Spectroscopy and Laser - Raman in Bladder Malignancy Diagnosis \ Essam Eigeily A/tined Ali ; Nafie A. AL Muslet .- Khartoum : Sudan univresity of science and technology , Institute Of Laser , 2009.- 124 P . : ill. ; 28cm .- PhD en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/14043
dc.description Thesis en_US
dc.description.abstract Bladder cancer is one of the most common cancers In Africa. It takes several days to reach a diagnosis using histological examinations of specimens obtained by endoscope, which increases the medical expense. Spectroscopic analysis of bladder cancer tissues has received considerable attention due to its sensitivity to biochemical variations in the samples. The present study investigated the usc of FTIR and laser Raman spectrometer as a diagnose tools of bladder cancer. Fourty two bladder samples were collected from 21 patients during surgery from different hospitals without any pretreatment. FTIR, with a ceramic source, was used to differentiate between normal and cancerous bladder tissues via the change in the spectra of these samples. The investigations detected obvious spectroscopic change in the proteins (1650,1550 ern"), lipids (2925,2850 em") and nucleic acid (l080, 1236 ern"). With FT Raman spectrometer supplied by Nd: YAG laser, as an excitation source, some of the samples were studied and a significant difference between the normal and cancerous bladder tissues were found around Raman shifts of 1650 ern", 1440 cm-1 , 1270 cm-I and 1080 e111-J................... en_US
dc.description.sponsorship Sudan University of Science & Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Laser en_US
dc.subject Laser Applications en_US
dc.subject Infrared en_US
dc.subject Malignancy Diagnosis en_US
dc.title Evaluation of Using Fourier Infrared Spectroscopy and Laser - Raman in Bladder Malignancy Diagnosis en_US