SUST Repository

Evaluation of Patient Dose in Conventional Chest and lumbar spine X-Ray using Skin Estimated Dose.

Show simple item record

dc.contributor.author Elbashier, Mona Elsafi Massaad
dc.contributor.author Supervisor,- Hussein Ahmed Hassan
dc.date.accessioned 2016-07-20T07:18:53Z
dc.date.available 2016-07-20T07:18:53Z
dc.date.issued 2016-04-27
dc.identifier.citation Elbashier, Mona Elsafi Massaad. Evaluation of Patient Dose in Conventional Chest and lumbar spine X-Ray using Skin Estimated Dose/Mona Elsafi Massaad Elbashier;Hussein Ahmed Hassan.-Khartoum:Sudan University of Science and Technology,College Radiologic Sciences,2016.-55p:ill;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/13812
dc.description Thesis en_US
dc.description.abstract This study aims to evaluate of patient radiation dose in chest x-ray using Entrance surface dose calculations, the study was done in two hospitals Alshab Teaching Hospital and Ibrahim Malik Teaching Hospital in Khartoum state, Entrance surface dose (ESD) was determined from exposure settings and patient information using mathematical equation . 220 patients were examined in this study, The entrance surface doses (ESDs) to patient undergoing chest X-ray radiography Exposure settings and patients data were recorded. Result concerning the kilovoltage (KVp) and tube current (mAs) and focus to film distance (FFD) settings. The variation in the patient doses and techniques used for the examinations studied were found among the different hospitals denoting the importance of establishing a national quality assurance programme and examination protocols to ensure patient doses are kept as Low as possible. Mean ESDs obtained for chest radiography in Alshab Teaching Hospital recorded in this study was ( .125 +0.04) mGy and Mean ESDs obtained for Lumbar spine radiography in Ibrahim Malik Teaching Hospital recorded in this study was (4.39 +1.23) mGy. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Radiologic Medical Sciences en_US
dc.subject Conventional Chest en_US
dc.subject lumbar spine en_US
dc.title Evaluation of Patient Dose in Conventional Chest and lumbar spine X-Ray using Skin Estimated Dose. en_US
dc.title.alternative تقييم جرعة المريض في تصوير الصدر والعمود الفقري في جهاز الأشعة السينية التقليدي باستخدام جرعة السطح المقدرة en_US
dc.type Thesis en_US