dc.contributor.author |
Abdelbari, Ahmed Osman Ahmed |
|
dc.contributor.author |
Supervised, -Ahmed Mostafa Abukonna |
|
dc.date.accessioned |
2016-05-24T05:21:05Z |
|
dc.date.available |
2016-05-24T05:21:05Z |
|
dc.date.issued |
2016-03-06 |
|
dc.identifier.citation |
Abdelbari, Ahmed Osman Ahmed.Estimation of Radiation Exposure in the Intensive Care Unit/ Ahmed Osman Ahmed Abdelbari;Ahmed Mostafa Abukonna .-Khartoum:Sudan University of Science and Technology,College of Radiology Medical Sciences,2016.-41p:ill;28cm.-M.Sc |
en_US |
dc.identifier.uri |
http://repository.sustech.edu/handle/123456789/13495 |
|
dc.description |
Thesis |
en_US |
dc.description.abstract |
In intensive care unit the patient checked with x ray periodically, the radiation protection procedures will be applied perfectly. However patients and their neighboring ones will receive radiation dose. This study aims to evaluate the received dose by staff and adjacent patient during mobile procedures in intensive care unit.
Radiation dose was measured for three months with thermoluminescent dosimeters (TLD); which was given to each of the two resident nurses; they were handed over to the next team during shift changeover. In addition, and one TLD was placed in the bed of adjacent patient who was not examined. One TLD was kept in the doctors' duty room which was within the premises of the ICU. Thus, a total of four TLDs were used in the study.
The result of the study revealed that the dose received by nurses, adjacent patient and resident doctor was 0.045(mSv), 0.069(mSv) and 0.022 (mSv) respectively. It found that if standard safety precautions were followed, cumulative radiation exposure to ICU resident doctor, nurses and adjacent patient was well within permissible limits and was not the cause of concern and hence routine personal dosimetric monitoring is not needed for residents in ICU. However, in view of changing practice, there is a need to repeat such audits periodically to monitor radiation exposure. |
en_US |
dc.description.sponsorship |
Sudan University of Science and Technology |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
Sudan University of Science and Technology |
en_US |
dc.subject |
Radiology Medical Sciences |
en_US |
dc.subject |
Radiation Exposure |
en_US |
dc.subject |
the Intensive Care Unit |
en_US |
dc.subject |
radiation dose. |
en_US |
dc.title |
Estimation of Radiation Exposure in the Intensive Care Unit |
en_US |
dc.title.alternative |
تقدير التعرض الاشعاعي في وحدة العناية المكثفة |
en_US |
dc.type |
Thesis |
en_US |