Assessment of conventional x-ray machine resolution using modulation transfer function

Show simple item record

dc.contributor.author Mohmed Ahmed, Salma Salah Eldeen Edreis
dc.contributor.author Supervisor, Mohamed Elfadil Mohamed
dc.date.accessioned 2016-03-14T10:12:28Z
dc.date.available 2016-03-14T10:12:28Z
dc.date.issued 2015-03-12
dc.identifier.citation Mohmed Ahmed, Salma Salah Eldeen Edreis .Assessment of conventional x-ray machine resolution using modulation transfer function/Salma Salah Eldeen Edreis Mohmed Ahmed;Mohamed Elfadil Mohamed.-Kartoum:Sudan University of Science and Technology,College Radiologic Sciences,2015.-44p:ill;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/12947
dc.description Thesis en_US
dc.description.abstract X-ray image resolution is important for resolving different structure since the diagnosis depends on visual perception ; therefore the main object of this study was to assess the diagnostic X-ray machine resolution using MTF in order to find the optimum exposure factor that preserve X-ray machine resolution. In order to determine the spatial resolution and to find the optimum KV, the phantom is placed on the detector surface then an image is acquired, with constant equal to 2 and KV of 40, 42, 44 and 46 kVp respectively. The images of the phantom were scanned to a computer, and Interactive Data Language IDL was used to apply modulation transfer function for the lines image to find the resolution for different KV and thickness. The result of this study showed that the resolution at 40 KV is better for the object image with low frequency 0.5 cycle/mm at 40 KV which is equal to 96% and reach 100% at 44 KV. The object with higher frequency 0.63 it is resolution increases from 48% at 40 KV progressively till it reach 92% at 46 KV. In summary the resolution get better for object image with higher frequency as the x-ray quanta increases but objects with lower frequency approaches the optimum level before that considerably. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Radiologic Sciences en_US
dc.subject X-ray en_US
dc.subject conventional machine en_US
dc.title Assessment of conventional x-ray machine resolution using modulation transfer function en_US