SUST Repository

Evaluation of Radiation Dose for Computed Tomography of Kidney Ureter and Bladder Protocol

Show simple item record

dc.contributor.author Zidan, Mogahid Mohammed Ahmed
dc.contributor.author Supervisor, - Ikhlas Abdelaziz Hassan Mohammed
dc.date.accessioned 2016-02-29T10:26:39Z
dc.date.available 2016-02-29T10:26:39Z
dc.date.issued 2015-11-05
dc.identifier.citation Zidan,Mogahid Mohammed Ahmed.Evaluation of Radiation Dose for Computed Tomography of Kidney Ureter and Bladder Protoco/Mogahid Mohammed Ahmed Zidan;Ikhlas Abdelaziz Hassan Mohammed.-Khartoum:Sudan University of Science and Technology,College of Radiology Medical Sciences,2015.-84p:ill;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/12861
dc.description Thesis en_US
dc.description.abstract Computed tomography (CT), is an x-ray procedure that generates high quality cross sectional images of the body, and by comparison to other radiological diagnosis, CT is responsible for higher radiation dose to patients. The radiation dose was measured in three hospitals in Khartoum state during (April to September 2015) using different CT modalities. In this study, the mean of dose for 64 slice was (924.5±81.12 mGy.cm). The mean of dose for 16 slice (689.1 ±92.5 mGy.cm). The mean of dose in 4 slice was (401.96± 108.3 mGy.cm). The dose is median than that reported in previous studies. The radiation dose higher in Al-zytoun hospital than Al-Fisal and Khartoum hospitals. MSCT scanners 64 slice exposed patients to a higher dose than MSCT scanners16 slice, and MSCT scanners16 slice exposed patients to a higher dose than MSCT scanners 4 slice. The radiologists and CT technologists must be trained to adapt CT scanning techniques based on clinical indications and to assess associated radiation doses with different scanning parameters. The results presented will serve as a baseline data needed for deriving reference doses for KUB examinations in Sudan. en_US
dc.description.sponsorship Sudan University of Sciences and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Kidney Ureter en_US
dc.subject Radiation Dose en_US
dc.title Evaluation of Radiation Dose for Computed Tomography of Kidney Ureter and Bladder Protocol en_US
dc.title.alternative تقويم الجرعة الاشعاعية في نظام التصوير المقطعي للكلى والحالب والمثانة en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search SUST


Browse

My Account