Measurement of Exposure Level during Technetium Generator Elusion at Nuclear Medicine lab

Show simple item record

dc.contributor.author Elteraify, Hind Eltag
dc.contributor.author Supervisor,-Mohammed Ahmed Ali Ome
dc.date.accessioned 2015-12-09T09:19:41Z
dc.date.available 2015-12-09T09:19:41Z
dc.date.issued 2015-11-03
dc.identifier.citation Elteraify,Hind Eltag.Measurement of Exposure Level during Technetium Generator Elusion at Nuclear Medicine lab/Hind Eltag Elteraify;Mohammed Ahmed Ali Omer.-khartoum:Sudan University of Science and Technology,College of Medical Radiologic Science,2015.-38p.:ill.;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/12239
dc.description Thesis en_US
dc.description.abstract The following experimental study has been carried out at radiation and Isotopes Center of Khartoum in Sudan, aiming to determine technetium generator time activity curve i.e. decay process, dose measurement received by the technologist hands, the exposure level relative to distance at hot lab and the cycle of waste management. With the usage of Geiger Muller survey detector the exposure level at different points, hands, and abdomen of the technologists have been measured, as well the radioactive waste management has been assessed and compared with IAEA recommendation. The obtained results showed that: The technetium generator has a time activity curve that fits the exponential equation of the following form: y = 886.2e-0.25x, where x refers to days and y refers to the relative activity. And the exposure level at different points distal from the generator could be calculated based on the following equation y = 24.26e-0.63x, where x refers to the point and y refers to the accumulative dose during generator working days. And the technologist’s hands received radiation dose of 34 (mCi/h) and the abdomen received a dose of 4.5 (mCi/h). And the waste management has been carried out based on the IAEA recommendation. en_US
dc.description.sponsorship Sudan University of Science &Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University for Sciences and Technology en_US
dc.subject Medical Radiologic en_US
dc.subject nuclear medicine en_US
dc.subject Measurement of Exposure en_US
dc.subject at Nuclear Medicine lab en_US
dc.title Measurement of Exposure Level during Technetium Generator Elusion at Nuclear Medicine lab en_US
dc.title.alternative قياس مستوى التعرض أثناء استحلاب مولد التكنيشيوم بمعمل الطب النووي en_US
dc.type Thesis en_US