Design and Implementation of Accurate PC- based Electro-cardiograph System

Show simple item record

dc.contributor.author Edris, Ibtihal Hassan El-Shekh
dc.contributor.author Supervisor - Mohamed Yagoub Esmail
dc.date.accessioned 2015-12-01T10:53:34Z
dc.date.available 2015-12-01T10:53:34Z
dc.date.issued 2015-10-10
dc.identifier.citation Edris,Ibtihal Hassan El-Shekh .Design and Implementation of Accurate PC- based Electro-cardiograph System /Ibtihal Hassan El-Shekh Edris ;Mohamed Yagoub Esmail .- Khartoum: Sudan University of Science and Technology, college of Engineering,2015 .-58p. :ill. 28cm .-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/12121
dc.description Thesis en_US
dc.description.abstract ECG is a very important device in the diagnosis and because it can determine the health status of the heart by display ECG signal . And on the side of health care must be the ECG precise and does not contain any defect or problem and in order to protect the patient and ensure the healthy him. In this study Design and Implementation of accurate PC-Based Electro-cardiograph system has been introduced, and successfully tested. In order to Design and Implementation of accurate PC-Based Electro-cardiograph system, design ECG simulator first to create ECG signal identical from human body by using 2 integrated circuit (HEF4521B & HCF4017B) and some of the resistors and capacitors , and design ECG device secondly by using the instrumentation amplifier (AD642) and low pass filter ,high pass filter, notch filter. Where in the testing phase is connected ECG simulator with ECG device , after ensure the safety of the machine ,the patient's connected with the ECG device and these are called diagnostic phase. The last part in this project is how use PC in order to display the ECG signal, using microcontroller to convert analog signal into digital signal and sent digital information to serial port , using software to display signal on computer. The implantation of this system in (Al Shaab Hospital ,Omdurman hospital) the system produced accuracy of 81.8% and sensitivity of 83.3%. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Biomedical Engineering en_US
dc.subject Electric ECG en_US
dc.title Design and Implementation of Accurate PC- based Electro-cardiograph System en_US
dc.title.alternative تصميم وتنفيذ نظام دقيق لتخطيط كهربائية القلب باستخدام الحاسوب en_US
dc.type Thesis en_US