SUST Repository

Design of Heart Sound Biometric Access Control System

Show simple item record

dc.contributor.author Mustafa, HaramMohammed Alfateh Mohammed
dc.contributor.author Supervisor - Abuagla Babiker Mohammed Babiker
dc.date.accessioned 2015-11-09T11:09:11Z
dc.date.available 2015-11-09T11:09:11Z
dc.date.issued 2015-08-10
dc.identifier.citation Mustafa,HaramMohammed Alfateh Mohammed.Design of Heart Sound Biometric Access Control System / HaramMohammed Alfateh MohammedMustafa;Abuagla Babiker Mohammed Babiker.-Khartoum: Sudan University of Science and Technology, College of Engineering, 2015 .-134p. :ill. ;28cm .-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/11800
dc.description Thesis en_US
dc.description.abstract This project reviews the extent to using of heart sound as biometric system used to identify the person and verify him. Features that have been chosen for this purpose are energy of heart sound signal and power spectrum.The heart sounds were collected from the internet. A matrix laboratory (MATLAB) algorithm was implemented to design a program that used discrete wavelet transform (DWT) for de-noising the signal, continuous wavelet transform (CWT) and Mel Frequency Cepstrum Coefficients (MFCC) for feature extraction and then a databases were build holding sounds features. Finally, Euclidean distance was used for classification sounds and display result depending on mode of operation (identification or verification mode). The program code was implemented in Graphical User Interface (GUI) to easy use of application. Then RS232 was interfaced between it and simulation circuit that consist of ATMEGA 16 (microcontroller), which simulate program via Bascom-AVR as programming language then Proteus was used to verify the code, it was displayed the name of person if the application in identification mode or allowed to access if in verification mode. The application which was programmed and simulated gave a 22.35% error in identification mode when used energy signature and gave a 15.29% error in identification mode when used power spectrum signature. en_US
dc.description.sponsorship Sudan University of Science and Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Mechatronic Engineering en_US
dc.subject Control System en_US
dc.subject Heart Sound en_US
dc.subject Sound Biometric en_US
dc.title Design of Heart Sound Biometric Access Control System en_US
dc.title.alternative تصميم نظام تحكم للولوج بإستخدام صوت القلب كبصمة حيوية en_US
dc.type Thesis en_US