SUST Repository

Assessment of Plasma D-dimer in Preeclamptic Pregnant Women in Khartoum State

Show simple item record

dc.contributor.author Abbas, Mawada Musa Ahmed
dc.contributor.author Supervisor,- Noon Babiker Mohammed Ahmed
dc.date.accessioned 2015-10-06T08:47:46Z
dc.date.available 2015-10-06T08:47:46Z
dc.date.issued 2015-06-01
dc.identifier.citation Abbas,Mawada Musa Ahmed.Assessment of Plasma D-dimer in Preeclamptic Pregnant Women in Khartoum State/Mawada Musa Ahmed Abbas;Noon Babiker Mohammed Ahmed.-Khartoum:Sudan University of Science and Technology,Medical Laboratory Science,2015.-50p.:ill.;28cm.-M.Sc. en_US
dc.identifier.uri http://repository.sustech.edu/handle/123456789/11628
dc.description Thesis en_US
dc.description.abstract dimer was measured by using Nycocard d-dimer,and results were analyzed using statistical of package social science (SPSS), computer program. Result:The study results showed that the level of D-dimer was significantly increase (P =0.017) in hypertensive preeclamptic pregnant women. Means±SD cases versus controls (1.040±0.45 versus 0.31±0.139). In preeclamptic pregnant women group, the level of D-dimer showed significant strong positive correlation with the duration of hypertension appear(P=0.000). Also the findings of this study Background:Preeclampsia is a multifactorial disease characterized by high blood pressure and proteinuria after the 20th week of pregnancy. Preeclampsia is associated with microvasculature fibrin deposition and maternal organ dysfunction. D-dimer has been used as a marker of production/ degradation of fibrin in vivo. Objective:TOassess plasma D-dimer in preeclampticpregnant womento find out the effect of hypertension duration and body mass index on the parameter. Materials and methods: This is case control study. The study was conducted from March to June 2015, and sixty samples from normotensive pregnant women as controlchosen randomly from Soba university hospital. All samples were tested for D-dimer.Dshowed that, there was a significant strong positive correlation between level of D-dimer and BMI (P=0.003). Conclusion:From the result of this study, it is concluded that; the level of D-dimer was significantly increased in preeclamptic pregnant women and correlated with duration and BMI. en_US
dc.description.sponsorship Sudan University of Science & Technology en_US
dc.language.iso en en_US
dc.publisher Sudan University of Science and Technology en_US
dc.subject Plasma D-dimer en_US
dc.subject Preeclamptic Pregnant en_US
dc.title Assessment of Plasma D-dimer in Preeclamptic Pregnant Women in Khartoum State en_US
dc.title.alternative تقويم مستوى دايمر(د) في بلازما الدم لدى النساء الحوامل المصابات بإرتفاع ضغط الدم في ولاية الخرطوم en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search SUST


Browse

My Account