dc.contributor.author |
Elnour, Abdelrahman Mohamed |
|
dc.contributor.author |
Supervisor - Abdelmoneim Adam Suleiman |
|
dc.date.accessioned |
2015-08-19T10:31:13Z |
|
dc.date.available |
2015-08-19T10:31:13Z |
|
dc.date.issued |
2015-01-01 |
|
dc.identifier.citation |
Elnour, Abdelrahman Mohamed.ESTABLISHMENT OF DIAGNOSTIC REFERENCE LEVEL FOR COMPUTED TOMOGRAPHY (CT) IN SUDAN\Abdelrahman Mohamed Elnour ; Abdelmoneim Adam Suleiman .-khartoum:Sudan University of science & Technology,College of Medical Radiologic Science,2015.-147p.:ill.;28cm.-Ph.D. |
en_US |
dc.identifier.uri |
http://repository.sustech.edu/handle/123456789/11492 |
|
dc.description |
Thesis |
en_US |
dc.description.abstract |
The use of X-ray radiation in the medical field is increasing steadily since
discovered for its great services in the discovery of the disease and in
treatment , so this study aimed to work to establish a level of exposure to
acceptable according to international standards without prejudice to
reduce the presence of medical imaging and desired information from the
tests and that called DRLS.
This study was done in the period between 2012 -2015 included 677
unchanged computed tomography average weight of between (65 kg to
75 kg ) and with its similarity to the complaint in a single examination
and then took the same 10 patients for each examination divided Imager
head , chest, abdomen and pelvis, according to the criteria traded on the
work DRLS on 17 Cross-Sectional center ray has focused on the study of
more centers and more frequency tests request .
The study included all devices CT scan in these centers, which range
between (2 slice to 128 Slice)
More than a statistical method used in it to represent the results and data
in order to calculate DRLS of the total statistical data which centered on
the concept of (DLP) and (CTDIV) basic units to create a diagnostic
reference dose for each individual center and then the value located at the
account (75%-3 rd quartile) DRLS per centers and identify NDRL full
range representing .DRL
The study showed follows
First in brain imaging that there is a difference in the level of radiation
exposure from center to center in spite of its similarity to the same center
and the same device has been found that the difference in the use of
exposing the top factors such as current for priming and increasing the
IIIslide area and either increase the area under examination and either of the
weakness in the training and calculates the DRL to portray the brain It
shows that (75%) corresponding to the value in (1209 mGy.sm)
Second, a CT scan of the chest showed a large study differences are in
some of the centers, to a difference in the method used screening and
factors used in the exposure to radiation. The DRLS in 75% (650 mGy /
cm)
Thirdly number (179) patients of the abdomen and pelvis, especially in
patients with urinary tract tests to check routinely The study showed that
DRLS (75%) of the data is located in the (978 mGy / cm)
The study concluded I'm there a lot of tests are ordered to incomplete
information in the request for examination , leading to a repeat
examination more than once as this study an effort to develop a plan and
path of the road starts from him and that the lack of previous studies of
this area in the Sudan in this area had to be that the other studies deeper
and more comprehensive in order to increase the quality of medical
imaging , which in turn is to increase its presence in providing highest
quality and diagnostic tests less Take and underestimate exposure to
radiation damage . |
en_US |
dc.description.sponsorship |
Sudan University of Science and Technology |
en_US |
dc.language.iso |
en |
en_US |
dc.publisher |
Sudan University of Science and Technology |
en_US |
dc.subject |
SUDAN |
en_US |
dc.subject |
CT |
en_US |
dc.subject |
TOMOGRAPHY |
en_US |
dc.subject |
DIAGNOSTIC |
en_US |
dc.subject |
LEVEL |
en_US |
dc.subject |
REFERENCE |
en_US |
dc.subject |
COMPUTED |
en_US |
dc.subject |
Radiologic Technology |
en_US |
dc.title |
ESTABLISHMENT OF DIAGNOSTIC REFERENCE LEVEL FOR COMPUTED TOMOGRAPHY (CT) IN SUDAN |
en_US |
dc.title.alternative |
انشاء المستوى المرجعى لفحوصات الاشعة المقطعية التشخيصية في السودان |
en_US |
dc.type |
Thesis |
en_US |