Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/9462
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAlhaj, Mamdouh Balla Edris
dc.contributor.authorAlzubair, Mohmmed Babekir Alamen
dc.contributor.authorA.Gadir, Wail Mohammed Alzain
dc.contributor.authorSupervisor - Sumya Abdelmoneim
dc.date.accessioned2014-12-31T09:52:09Z
dc.date.available2014-12-31T09:52:09Z
dc.date.issued2014-09-01
dc.identifier.citationAlhaj,Mamdouh Balla Edris.Evaluation and Control of Evaporation Losses fromGasoline Internal Floating Roof Tanks/Mamdouh Balla Edris Alhaj,Mohmmed Babekir Alamen Alzubair, Wail Mohammed Alzain A.Gadir; Sumya Abdelmoneim‬‬.-Khartoum: Sudan University of Science and Technology ,College of Petroleum Engineering and Technology,2014.-88P. : ill. ; 28Cm.-B.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/9462
dc.descriptionB.Sc.en_US
dc.description.abstractGasoline is a Volatile Organic Compounds (VOCs) with different boiling point range of (30-200) ºC. The lightcompounds that have boiling point of less than 40 ºC constitute about 10V %. The objective of this study is to evaluate the amount of evaporation loss of gasoline frominternal floating roof storage tank. The case study is based on U.S Environmental Protection Agency Data (USEPA) the evaporation loss calculation is accomplished by company (A). By comparing the different rim seal system liquid it was found that liquid mounted seal with rim mounted secondary has minimum evaporation loss (4068.19 Ib/yr ) ,which equals toless than (50%) of vapor mounted seal primary only (8679 Ib/yr),so it is most suitable for internal floating roof tanks. Reduction of evaporation loss of gasoline will give attractive economic returns aswell as reducing air pollution and hazards. This reduction could be achieved byplantation of the depots and increase the shadow area around tanks, and reducethe wind speed which would be considered as metrological conditions control action. in addition to the future tank design consideration and mechanicalupgrades for the existing one.en_US
dc.description.sponsorshipSudan University of Science and Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectTransportation and Refining Engineeringen_US
dc.subjectInternal Floating Roof Tanksen_US
dc.subjectDeck Fitting Lossen_US
dc.subjectDeck seam Lossen_US
dc.subjectGasolineen_US
dc.subjectRim Seal Lossen_US
dc.subjectWthdrawalen_US
dc.subjectEvaporation Lossen_US
dc.titleEvaluation and Control of Evaporation Losses fromGasoline Internal Floating Roof Tanksen_US
dc.title.alternativeالتقييم و التحكم في فواقد التبخر من خزاناتالجازولين ذات السقوف العائمة الداخليةen_US
dc.typeThesisen_US
Appears in Collections:Bachelor of Petroleum Engineering & Technology

Files in This Item:
File Description SizeFormat 
Evaluation and Control of Evaporation .pdfResearch1.87 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.