Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/5440
Title: Application of New Technology to Substations Automation
Other Titles: تطبیق تقنیة جدیدة لأتمتة المحطات الفرعیة
Authors: Galaleldin, Fakhereldin Zeinelabdin
Supervisor,- Awadalla Tayfour Ali
Keywords: Electrical Engineering
(Control and Microprocessor
Substations Automation
Issue Date: 1-Feb-2011
Publisher: Sudan University of Science and Technology
Citation: Galaleldin,Fakhereldin Zeinelabdin.Application of New Technology to Substations Automation/Fakhereldin Zeinelabdin Galaleldin;Awadalla Tayfour Ali.-Khartoum:Sudan University of Science and Technology,College of Engineering,2011.-84P:ill. ; 28 cm.-M.Sc.
Abstract: The amount of information, which is generated in the substation automation systems, has grown exponentially since the introduction of intelligent electronic devices (IED). Until recent years substation communication between IED was realized with proprietary protocols. This led to communication problems in the system with IEDs from different vendors, and made many organizations to suffer from economical and technical sanction or companies’ monopoly. The International Electro-technical Commission IEC 61850 standard was introduced in order to harmonize substation communication and gain interoperability between several vendors. The conventional information communication exchange between devices was hardwiring cables information exchange. Recently Generic Object Oriented Substation Events (GOOSE) communication is used. GOOSE enables the transmission of these signals via Ethernet network, therefore creating a system that is more easily expandable, easy to maintain and reducing of hard wiring cost. The standard divides substation communication into three levels, station level, bay level and process level. This study is focusing on Generic Object Oriented Substation Events (GOOSE) communication between Intelligent Electronic Devices (IED) in the bay level and its applications. International Electro technical Commission IEC61850 uses Substation Configuration Language (SCL), which is based on Extensible Markup Language (XML) for the configuration of the automation system. The configuration includes substation topology, addressing and substation specification. The specifications are to be produced with software designed for this task. In this study the configuration software tool in use is (HELINK STS).
Description: Thesis
URI: http://repository.sustech.edu/handle/123456789/5440
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Application of New Technology .pdftitle48.84 kBAdobe PDFView/Open
Dedication.pdfDedication6.27 kBAdobe PDFView/Open
Acknowledgement.pdfAcknowledgement7.94 kBAdobe PDFView/Open
Table of contents.pdfcontents65.26 kBAdobe PDFView/Open
Abstract.pdfAbstract8.17 kBAdobe PDFView/Open
chapter one.pdf
  Restricted Access
chapter 17.11 kBAdobe PDFView/Open Request a copy
chapter two.pdf
  Restricted Access
chapter 319.24 kBAdobe PDFView/Open Request a copy
Chapter three.pdf
  Restricted Access
chapter 635.84 kBAdobe PDFView/Open Request a copy
chapter four.pdf
  Restricted Access
chapter 209.36 kBAdobe PDFView/Open Request a copy
chapter five.pdf
  Restricted Access
chapter 591.4 kBAdobe PDFView/Open Request a copy
CHAPTER SIX.pdf
  Restricted Access
chapter 17.64 kBAdobe PDFView/Open Request a copy
Appendices .pdfAppendices 22.38 kBAdobe PDFView/Open
LIST OF BBREVIATIONS1.pdfLIST 14.92 kBAdobe PDFView/Open
LIST OF FIGURS1.pdfLIST 12.24 kBAdobe PDFView/Open
List of tables1.pdfLIST 7.22 kBAdobe PDFView/Open
Project presentation.pdfProject 1.14 MBAdobe PDFView/Open
Referenses.pdfReferenses9.61 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.