Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/3731
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAhmed, Maha Gaffer AbdElkalig
dc.contributor.authorSupervisor,-Mohammed Ahmed Ali Omer
dc.date.accessioned2014-03-02T11:39:29Z
dc.date.available2014-03-02T11:39:29Z
dc.date.issued2011-01-01
dc.identifier.citationAhmed ,Maha Gaffer AbdElkalig.Measurement of x-ray Machines Output Using Polyvinyl Alcohol AgNo3 Nancomposites Film/Measurement of x-ray Machines Output Using Polyvinyl Alcohol\AgNo3 Nancomposites FilmAhmed;Mohammed Ahmed Ali Omer.- Khartoum :sudan university of science and technology, Medical Radiologic Sciences,2011. 46p. : ill . ;28cm .- M.Sc.en_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/3731
dc.descriptionThesisen_US
dc.description.abstractRadiation technicians usually exposed for different levels of X-rays while they are working, which may cause the potential damages. To avoid this case they must use monitoring devices such as Film Badge, TLD Badge or Pocket Dosimeter.  In this study a film was prepared film by dissolving PVA powder (5 wt %) in distilled water under the controlled water bath at 60-70 oC and continuous stirring for 3 hours. After that, concentration of 0.2 wt% of AgNO3 was added in a dark room and stirred for 2 hours. The blend solutions were poured into Petri-Dishes and keep it to dry under ambient temperature for 3 days in a dark room. Then the film was exposed to different energies of time from the X-ray mechanic then used UV/Vis spectrophotometer.  Then the intensity of light passing through the film (I) was measured, and compared it to the intensity of light before it passes through the film (IO). and was found that when increased the level of dose the level of the film absorption was increased and when the dose level decreased the film absorption was decreased and the highest absorption is accuse at dose 368Gy and the lowest absorption at 288Gy because the dose increases due to the reduction of Ag+ to Ag0, but the band gap decreases from 3.14749E-30eV to 2.96224E-30eV when the doses increased from 288Gy to 368Gy.en_US
dc.description.sponsorshipsudan university of science and technologyen_US
dc.language.isoenen_US
dc.publishersudan university of science and technologyen_US
dc.subjectMeasurementen_US
dc.subjectx-rayen_US
dc.titleMeasurement of x-ray Machines Output Using Polyvinyl Alcohol\AgNo3 Nancomposites Filmen_US
dc.typeThesisen_US