Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/26345
Title: Investigations Of Heat Stress Parameters Onfoundries Workers Productivity
Other Titles: تقييم عوامل الاجهاد الحراري على إنتاجية عمال المسابك
Authors: Mohammed, Aallaa Mohammed Mohi-Eldeen
Supervisor, -Yassin Mohamed Hamdan
Keywords: Engineering
Mechanical Engineering
Heat Stress Parameters
Onfoundries Workers Productivity
Issue Date: 27-Dec-2019
Publisher: Sudan University of Science and Technology
Citation: Mohammed, Aallaa Mohammed Mohi-Eldeen .Investigations Of Heat Stress Parameters Onfoundries Workers Productivity \ Aallaa Mohammed Mohi-Eldeen Mohammed ; Yassin Mohamed Hamdan .- Khartoum: Sudan University of Science and Technology, College of Engineering, 2019.- 56 p: ill;28cm.- M.Sc
Abstract: The aimof this study is to measure the workplace heat stress in different sections of the foundries. The study was carried out in ALBYAN foundries. The heat is measured infurnace worker site, casting site, molds forming site, iron gathering point,power worker point , arm worker, crane worker, worker waiting point and finishing pointmeasuring the dry bulb temperature(TDB °C), wet bulb temperature(TWB °C), globe temperature(TG °C), wet bulb globe temperature(WBGT °C), and the relative humidity(RH%) at the work places. Extremely high levels of WBGT index was found in arm workerwith an average of 29.77 °C followed by 29.13 °C in power worker point. The mean WBGT mean values obtained in other sections were26.67 °C in crane worker, 24.18°C in furnace worker,24.14°C in worker waiting point,23.17°C in Iron gathering point,22.93°C in finishing point , 22.73°C in iron ore area, 22.70°C in molds forming site and 22.65°C in casting site. The mean WBGT index levels are significantly higher in near the arm worker, power worker point,crane worker and furnace worker.The prescribed standard threshold limit value (TLV) of WBGT level was high in near the arm worker, power worker point, crane worker and furnace worker. The values of equivalent noise levels were under control as per OSHA guidelines in all the process sections. The heat may increase the health risk of worker with reduce the efficiency and consequently affect the production of the unit. The recommendations should be taken as indicative of stress areas and workers should be under constant medical supervision.
Description: Thesis
URI: http://repository.sustech.edu/handle/123456789/26345
Appears in Collections:Masters Dissertations : Engineering

Files in This Item:
File Description SizeFormat 
Investigations Of Heat Stress ... .pdfResearch2.2 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.