Please use this identifier to cite or link to this item: https://repository.sustech.edu/handle/123456789/26032
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMohammed, Khansaa Ahmed AwadEljeed-
dc.contributor.authorSupervisor, -Eltayeb Wagiallah Eltayeb Wagiallah-
dc.date.accessioned2021-04-19T08:54:53Z-
dc.date.available2021-04-19T08:54:53Z-
dc.date.issued2021-01-10-
dc.identifier.citationMohammed, Khansaa Ahmed AwadEljeed . Assessment of Gamma Camera Quality Control Performance in National Cancer Institute -Wad Madani \ Khansaa Ahmed AwadEljeed Mohammed ; Eltayeb Wagiallah Eltayeb Wagiallah .- Khartoum:Sudan University of Science and Technology,College of Medical Radiologic Science,2021.- 50 p.:ill.;28cm.-M.Scen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/26032-
dc.descriptionThesisen_US
dc.description.abstractThis study was performed to assess the performance of gamma camera Quality Control system in National Cancer Institute-Wad Madani department of nuclear medicine for the following parameters: uniformity, energy resolution and physical inspection peaking using Tc99m. the samples of this study for quality control reading includes 61 (readings), Extrinsic uniformity 52, Energy resolution 9. Were the data collected in period from January to June 2020. All results that was obtained from the study have been compared with the acceptance limits with International Atomic Energy Agency and National Electricals Manufacturing Association -2001 standards. The result reveal that the extrinsic uniformity for differential and integral were in the accepted limits that established by NEMA for the hospital, and the value of energy resolution was 5.43%, 5.66%, and the energy resolution showed a central peak of the energy at 140 KeV. The research concluded that the value of the results of the gamma camera that was obtained from national cancer institute was closed to the standard set by International Atomic Energy Agency (IAEA) and the National Electricals Manufacturing Association(NEMA).en_US
dc.description.sponsorshipSudan University of Science & Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science & Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectMedical Physicsen_US
dc.subjectGamma Cameraen_US
dc.subjectQuality Control Performanceen_US
dc.subjectNational Cancer Institute -Wad Madanien_US
dc.titleAssessment of Gamma Camera Quality Control Performance in National Cancer Institute -Wad Madanien_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Assessment of Gamma .... .pdfResearch2.07 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.