dc.identifier.citationAbdulgader, Mauda Abdulgader Mohammed . Assessment of Radiation Dose and Noise in Chest Computed Tomography Examination \ Mauda Abdulgader Mohammed Abdulgader ; Hussein Ahmed Hassan .- Khartoum:Sudan University of Science and Technology,College of Medical Radiologic Science,2020.-55p.:ill.;28cm.-M.Scen_US
dc.identifier.urihttp://repository.sustech.edu/handle/123456789/25691-
dc.descriptionThesisen_US
dc.description.abstractThis research aims to assess radiation dose and noise for chest during CT examination in four centers of diagnostic images , A total of 100 patient undergoing chest CT exams ,CT machine were used to collect data during this study , General Electric(GE) optima ,GE bright speed, GE health care manufactured USA and Toshiba manufactured Japan .The radiation dose were assess using CTDIvol , DLP and noise was assessed by stander deviation in region of interest. all data analyzed using SPSS analysis. In this study I founded the mean effective dose, mean noise, mean Dose Length Product , CT Dose Index volume for chest in the first center (6.65msv), (13.84HU), (395.07mGy.cm), (11.57mGy) respectively, in second center (6.67msv), (8.79HU), (13.02mGy), (383.36mGy.cm), in 3rd center and (5.18msv), (11.34HU), (6.95mGy) and (280.89mGy.cm). In 4th center mean E (6.26msv), noise (15.08HU), DLP (385.51mGy.cm) and CTDI (12.37). The effective dose and noise were observed difference in this four centers ,the difference was due to type and age of machine ,chest protocol and parameter used Then the effective dose been compared with maximum permissible dose level MPDL and I founded with in MPDLs (2-20msv),the average dose length product and CT dose index volume compared with international diagnostic reference level and I were founded with in IDRLs for chest(650mGy.cm) (30mGy) respectively .en_US
dc.description.sponsorshipSudan University of Science & Technologyen_US
dc.language.isoenen_US
dc.publisherSudan University of Science and Technologyen_US
dc.subjectMedical Radiologic Sciencesen_US
dc.subjectMedical physicsen_US
dc.subjectRadiation Doseen_US
dc.subjectChest Computed Tomography Examinationen_US
dc.titleAssessment of Radiation Dose and Noise in Chest Computed Tomography Examinationen_US
dc.title.alternativeتقييم الجرعة الإشعاعية والتشويش في تصوير الصدر بالأشعة المقطعيةen_US
dc.typeThesisen_US
Appears in Collections:Masters Dissertations : Medical Radiologic Science

Files in This Item:
File Description SizeFormat 
Assessment of Radiation .....pdfResearch1.07 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.